{"title":"用钠作压力计流体测量钠蒸气压力","authors":"P. J. Erens, D. Kröger","doi":"10.1243/JMES_JOUR_1980_022_031_02","DOIUrl":null,"url":null,"abstract":"The pressure of saturated sodium vapour in the range 1114–47 500N/m2 is measured using a sodium manometer developed for this purpose. Commercially obtainable reactor grade sodium is used and is found to follow the equation log P= 9.36037-(5048–74/r), where P is in N/m2 and T in Kelvin.","PeriodicalId":114598,"journal":{"name":"Archive: Journal of Mechanical Engineering Science 1959-1982 (vols 1-23)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1980-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of Sodium Vapour Pressure Using Sodium as Manometer Fluid\",\"authors\":\"P. J. Erens, D. Kröger\",\"doi\":\"10.1243/JMES_JOUR_1980_022_031_02\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The pressure of saturated sodium vapour in the range 1114–47 500N/m2 is measured using a sodium manometer developed for this purpose. Commercially obtainable reactor grade sodium is used and is found to follow the equation log P= 9.36037-(5048–74/r), where P is in N/m2 and T in Kelvin.\",\"PeriodicalId\":114598,\"journal\":{\"name\":\"Archive: Journal of Mechanical Engineering Science 1959-1982 (vols 1-23)\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1980-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archive: Journal of Mechanical Engineering Science 1959-1982 (vols 1-23)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1243/JMES_JOUR_1980_022_031_02\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archive: Journal of Mechanical Engineering Science 1959-1982 (vols 1-23)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1243/JMES_JOUR_1980_022_031_02","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Measurement of Sodium Vapour Pressure Using Sodium as Manometer Fluid
The pressure of saturated sodium vapour in the range 1114–47 500N/m2 is measured using a sodium manometer developed for this purpose. Commercially obtainable reactor grade sodium is used and is found to follow the equation log P= 9.36037-(5048–74/r), where P is in N/m2 and T in Kelvin.