Mingshu Yao, Xiaofeng Xu, Zhenhe Ju, Bo Qv, Zhongyuan Zheng
{"title":"基于软阈值去噪的SF6小信号检测系统的研究与应用","authors":"Mingshu Yao, Xiaofeng Xu, Zhenhe Ju, Bo Qv, Zhongyuan Zheng","doi":"10.1145/3459104.3459131","DOIUrl":null,"url":null,"abstract":"The weak signal acquisition such as SF6 is affected by power frequency interference and sensor polarization voltage. If the integrated instrument amplifier is directly used as small signal amplifier, there are some problems, such as large data deviation. In this paper, a redundant monitoring system combining temperature compensation method and multi-stage gain is established, and the soft threshold denoising method is used to filter the interference signal, and the SF6 on-line data monitoring is realized by STM32F4 single chip microcomputer.","PeriodicalId":142284,"journal":{"name":"2021 International Symposium on Electrical, Electronics and Information Engineering","volume":"198 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research and Application of SF6 Small Signal Detection System Based on Soft Threshold Denoising Method\",\"authors\":\"Mingshu Yao, Xiaofeng Xu, Zhenhe Ju, Bo Qv, Zhongyuan Zheng\",\"doi\":\"10.1145/3459104.3459131\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The weak signal acquisition such as SF6 is affected by power frequency interference and sensor polarization voltage. If the integrated instrument amplifier is directly used as small signal amplifier, there are some problems, such as large data deviation. In this paper, a redundant monitoring system combining temperature compensation method and multi-stage gain is established, and the soft threshold denoising method is used to filter the interference signal, and the SF6 on-line data monitoring is realized by STM32F4 single chip microcomputer.\",\"PeriodicalId\":142284,\"journal\":{\"name\":\"2021 International Symposium on Electrical, Electronics and Information Engineering\",\"volume\":\"198 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-02-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Symposium on Electrical, Electronics and Information Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3459104.3459131\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Symposium on Electrical, Electronics and Information Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3459104.3459131","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research and Application of SF6 Small Signal Detection System Based on Soft Threshold Denoising Method
The weak signal acquisition such as SF6 is affected by power frequency interference and sensor polarization voltage. If the integrated instrument amplifier is directly used as small signal amplifier, there are some problems, such as large data deviation. In this paper, a redundant monitoring system combining temperature compensation method and multi-stage gain is established, and the soft threshold denoising method is used to filter the interference signal, and the SF6 on-line data monitoring is realized by STM32F4 single chip microcomputer.