改进的矢量网络分析仪(VNA)系统的宽带矢量校正测量

Christoph Schulze, W. Heinrich, J. Dunsmore, O. Bengtsson
{"title":"改进的矢量网络分析仪(VNA)系统的宽带矢量校正测量","authors":"Christoph Schulze, W. Heinrich, J. Dunsmore, O. Bengtsson","doi":"10.1109/arftg54656.2022.9896558","DOIUrl":null,"url":null,"abstract":"Vector corrected wideband measurements on a modified vector network analyzer system are presented using wideband modulated signals as stimulus. The modified system allows intermediate frequency (IF) bandWidths exceeding 5 GHz based on external wideband IF access, signal conditioning and digitalization. A combined RF and IF calibration has been developed that allows full-band calibration using CW excitation, while measurements are made with wideband modulated signals. Impedance measurements verify excellent accuracy at -59dB deviation for an electrically switched impedance which is only a few dB less than for narrowband measurements. Repeatability of calculated error terms for consecutive calibrations also show comparable performance as for narrow-band measurements. Wideband one-port impedance measurements at 12.5 GHz using a Schroeder signal with 500 MHz instantaneous bandwidth show less than -50dB deviation with coherent averaging even without correcting for mixer distortion.","PeriodicalId":375242,"journal":{"name":"2022 99th ARFTG Microwave Measurement Conference (ARFTG)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Wideband Vector Corrected Measurements on a Modified Vector Network Analyzer (VNA) System\",\"authors\":\"Christoph Schulze, W. Heinrich, J. Dunsmore, O. Bengtsson\",\"doi\":\"10.1109/arftg54656.2022.9896558\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Vector corrected wideband measurements on a modified vector network analyzer system are presented using wideband modulated signals as stimulus. The modified system allows intermediate frequency (IF) bandWidths exceeding 5 GHz based on external wideband IF access, signal conditioning and digitalization. A combined RF and IF calibration has been developed that allows full-band calibration using CW excitation, while measurements are made with wideband modulated signals. Impedance measurements verify excellent accuracy at -59dB deviation for an electrically switched impedance which is only a few dB less than for narrowband measurements. Repeatability of calculated error terms for consecutive calibrations also show comparable performance as for narrow-band measurements. Wideband one-port impedance measurements at 12.5 GHz using a Schroeder signal with 500 MHz instantaneous bandwidth show less than -50dB deviation with coherent averaging even without correcting for mixer distortion.\",\"PeriodicalId\":375242,\"journal\":{\"name\":\"2022 99th ARFTG Microwave Measurement Conference (ARFTG)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 99th ARFTG Microwave Measurement Conference (ARFTG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/arftg54656.2022.9896558\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 99th ARFTG Microwave Measurement Conference (ARFTG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/arftg54656.2022.9896558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种改进的矢量网络分析仪系统,以宽带调制信号为激励,进行矢量校正宽带测量。改进后的系统允许基于外部宽带中频接入、信号调理和数字化的中频(IF)带宽超过5ghz。已经开发了一种射频和中频组合校准,允许使用连续波激励进行全频段校准,同时使用宽带调制信号进行测量。阻抗测量验证了在-59dB偏差下电开关阻抗的优异精度,仅比窄带测量少几个dB。连续校准计算误差项的可重复性也显示出与窄带测量相当的性能。在12.5 GHz频段使用施罗德信号进行的宽带单端口阻抗测量显示,即使不校正混频器失真,相干平均误差也小于-50dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wideband Vector Corrected Measurements on a Modified Vector Network Analyzer (VNA) System
Vector corrected wideband measurements on a modified vector network analyzer system are presented using wideband modulated signals as stimulus. The modified system allows intermediate frequency (IF) bandWidths exceeding 5 GHz based on external wideband IF access, signal conditioning and digitalization. A combined RF and IF calibration has been developed that allows full-band calibration using CW excitation, while measurements are made with wideband modulated signals. Impedance measurements verify excellent accuracy at -59dB deviation for an electrically switched impedance which is only a few dB less than for narrowband measurements. Repeatability of calculated error terms for consecutive calibrations also show comparable performance as for narrow-band measurements. Wideband one-port impedance measurements at 12.5 GHz using a Schroeder signal with 500 MHz instantaneous bandwidth show less than -50dB deviation with coherent averaging even without correcting for mixer distortion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信