抑制一阶反射的透镜设计

J. Buchheister, C. Weth
{"title":"抑制一阶反射的透镜设计","authors":"J. Buchheister, C. Weth","doi":"10.1117/12.868917","DOIUrl":null,"url":null,"abstract":"Optical systems with a reflected light condition, e.g. microscopes with reflected light illumination or fundus cameras, need to have weak first order ghosts or even to be completely free from them. Sequential ray tracing can be used to control optical performance and reflections on a ray basis during optimization. This is significantly more efficient in computation time and convergence than the usual approaches with non-sequential ray tracing or reconfigured optical systems to cover all critical ghosts. An ophthalmic lens for a fundus camera was designed with first order reflections stripped out by applying sequential ray tracing. The merit-function only had to be completed under certain conditions guaranteeing the absence of any reflections. No additional reconfiguration of the optical system in the design software was necessary.","PeriodicalId":386109,"journal":{"name":"International Optical Design Conference","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Lens design with suppressed first order reflections\",\"authors\":\"J. Buchheister, C. Weth\",\"doi\":\"10.1117/12.868917\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Optical systems with a reflected light condition, e.g. microscopes with reflected light illumination or fundus cameras, need to have weak first order ghosts or even to be completely free from them. Sequential ray tracing can be used to control optical performance and reflections on a ray basis during optimization. This is significantly more efficient in computation time and convergence than the usual approaches with non-sequential ray tracing or reconfigured optical systems to cover all critical ghosts. An ophthalmic lens for a fundus camera was designed with first order reflections stripped out by applying sequential ray tracing. The merit-function only had to be completed under certain conditions guaranteeing the absence of any reflections. No additional reconfiguration of the optical system in the design software was necessary.\",\"PeriodicalId\":386109,\"journal\":{\"name\":\"International Optical Design Conference\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Optical Design Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.868917\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Optical Design Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.868917","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

具有反射光条件的光学系统,例如具有反射光照明的显微镜或眼底相机,需要具有弱的一阶鬼影,甚至完全没有它们。在优化过程中,顺序光线跟踪可用于控制光性能和基于光线的反射。这在计算时间和收敛性方面比通常使用非顺序光线跟踪或重新配置光学系统以覆盖所有关键幽灵的方法要有效得多。采用顺序光线追踪的方法,设计了一种滤除一阶反射的眼底相机镜片。只有在保证没有任何反射的某些条件下才能完成功绩函数。不需要在设计软件中对光学系统进行额外的重新配置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Lens design with suppressed first order reflections
Optical systems with a reflected light condition, e.g. microscopes with reflected light illumination or fundus cameras, need to have weak first order ghosts or even to be completely free from them. Sequential ray tracing can be used to control optical performance and reflections on a ray basis during optimization. This is significantly more efficient in computation time and convergence than the usual approaches with non-sequential ray tracing or reconfigured optical systems to cover all critical ghosts. An ophthalmic lens for a fundus camera was designed with first order reflections stripped out by applying sequential ray tracing. The merit-function only had to be completed under certain conditions guaranteeing the absence of any reflections. No additional reconfiguration of the optical system in the design software was necessary.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信