V. Kasik, M. Penhaker, J. Kubícek, M. Cerný, M. Augustynek, David Oczka, Alice Krestanova
{"title":"心电信号验证监测仪的设计与实现","authors":"V. Kasik, M. Penhaker, J. Kubícek, M. Cerný, M. Augustynek, David Oczka, Alice Krestanova","doi":"10.5220/0007248001270133","DOIUrl":null,"url":null,"abstract":"The paper deals with a design and consequent realization of a monitor tester for validation of the ECG devices, and patient’s monitors for the ECG measurement. In the paper, we describe the electrical design of the plug-in module, which is intended for a transmission of the digital data from the computer. Data are sent by using the controlling SW connected to the parallel port in the plug-in module. An essential part of the proposed module is the three-channel 12 bit D/A converter AD 7398. This converter is able to simultaneously send data from all the three outputs. The converter output is unipolar in the volts units. For this reason, the transmitted signals are adjusted by using the differential amplifiers in order to convert them to the bipolar. The signal’s amplitudes are decreased to the millivolts level by using the voltage dividers. On the base of this solution, the Einthoven ECG leads may be detected.","PeriodicalId":357085,"journal":{"name":"International Conference on Biomedical Electronics and Devices","volume":"144 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and Implementation of Monitor Tester for Validation of ECG Signals\",\"authors\":\"V. Kasik, M. Penhaker, J. Kubícek, M. Cerný, M. Augustynek, David Oczka, Alice Krestanova\",\"doi\":\"10.5220/0007248001270133\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper deals with a design and consequent realization of a monitor tester for validation of the ECG devices, and patient’s monitors for the ECG measurement. In the paper, we describe the electrical design of the plug-in module, which is intended for a transmission of the digital data from the computer. Data are sent by using the controlling SW connected to the parallel port in the plug-in module. An essential part of the proposed module is the three-channel 12 bit D/A converter AD 7398. This converter is able to simultaneously send data from all the three outputs. The converter output is unipolar in the volts units. For this reason, the transmitted signals are adjusted by using the differential amplifiers in order to convert them to the bipolar. The signal’s amplitudes are decreased to the millivolts level by using the voltage dividers. On the base of this solution, the Einthoven ECG leads may be detected.\",\"PeriodicalId\":357085,\"journal\":{\"name\":\"International Conference on Biomedical Electronics and Devices\",\"volume\":\"144 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Conference on Biomedical Electronics and Devices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5220/0007248001270133\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Biomedical Electronics and Devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5220/0007248001270133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design and Implementation of Monitor Tester for Validation of ECG Signals
The paper deals with a design and consequent realization of a monitor tester for validation of the ECG devices, and patient’s monitors for the ECG measurement. In the paper, we describe the electrical design of the plug-in module, which is intended for a transmission of the digital data from the computer. Data are sent by using the controlling SW connected to the parallel port in the plug-in module. An essential part of the proposed module is the three-channel 12 bit D/A converter AD 7398. This converter is able to simultaneously send data from all the three outputs. The converter output is unipolar in the volts units. For this reason, the transmitted signals are adjusted by using the differential amplifiers in order to convert them to the bipolar. The signal’s amplitudes are decreased to the millivolts level by using the voltage dividers. On the base of this solution, the Einthoven ECG leads may be detected.