{"title":"玻璃前炉的计算机分析","authors":"L. Chang, W. A. Poolos, F. J. Nelson","doi":"10.1109/IAS.1988.25202","DOIUrl":null,"url":null,"abstract":"A computer model, FHI, written to perform analytical mass and energy balances for glass forehearth cooling zones is discussed. Assumptions used to formulate the model are presented, together with results of a sample calculation. The interpretation and potential application of model results in control strategies are discussed.<<ETX>>","PeriodicalId":274766,"journal":{"name":"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Computer analyses of glass forehearths\",\"authors\":\"L. Chang, W. A. Poolos, F. J. Nelson\",\"doi\":\"10.1109/IAS.1988.25202\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A computer model, FHI, written to perform analytical mass and energy balances for glass forehearth cooling zones is discussed. Assumptions used to formulate the model are presented, together with results of a sample calculation. The interpretation and potential application of model results in control strategies are discussed.<<ETX>>\",\"PeriodicalId\":274766,\"journal\":{\"name\":\"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1988.25202\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1988.25202","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A computer model, FHI, written to perform analytical mass and energy balances for glass forehearth cooling zones is discussed. Assumptions used to formulate the model are presented, together with results of a sample calculation. The interpretation and potential application of model results in control strategies are discussed.<>