电力变压器中性点接地方法:故障特征分析

V. Helac, S. Smaka, S. Grebović, N. Oprasic
{"title":"电力变压器中性点接地方法:故障特征分析","authors":"V. Helac, S. Smaka, S. Grebović, N. Oprasic","doi":"10.1109/ISGT-Europe54678.2022.9960344","DOIUrl":null,"url":null,"abstract":"The method of power transformer neutral point grounding is very important for power distribution network operation because it strongly affect the shapes and values of overvoltages and fault currents. Many methods of grounding are used in medium voltage (MV) power distribution networks. The selection of grounding method largely depends on the characteristics of power network connected to the substation. It is also necessary to consider the advantages and disadvantages of various neutral grounding methods during selection process to find the best solution from a technical and economical point of view. The effects of grounding methods on the characteristics of single-phase short circuit fault are discussed in this paper on the example of 110/20 kV substation ′′Bugojno′′. Modeling and simulation of the considered substation, power transmission and distribution lines are implemented in EMTP-RV software.","PeriodicalId":311595,"journal":{"name":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","volume":"288 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Power Transformer Neutral Point Grounding Methods: Analysis of Fault Characteristics\",\"authors\":\"V. Helac, S. Smaka, S. Grebović, N. Oprasic\",\"doi\":\"10.1109/ISGT-Europe54678.2022.9960344\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The method of power transformer neutral point grounding is very important for power distribution network operation because it strongly affect the shapes and values of overvoltages and fault currents. Many methods of grounding are used in medium voltage (MV) power distribution networks. The selection of grounding method largely depends on the characteristics of power network connected to the substation. It is also necessary to consider the advantages and disadvantages of various neutral grounding methods during selection process to find the best solution from a technical and economical point of view. The effects of grounding methods on the characteristics of single-phase short circuit fault are discussed in this paper on the example of 110/20 kV substation ′′Bugojno′′. Modeling and simulation of the considered substation, power transmission and distribution lines are implemented in EMTP-RV software.\",\"PeriodicalId\":311595,\"journal\":{\"name\":\"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"volume\":\"288 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGT-Europe54678.2022.9960344\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-Europe54678.2022.9960344","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电力变压器中性点接地方式对配电网过电压和故障电流的形态和值有很大影响,对配电网的运行具有重要意义。在中压配电网中,接地方法有很多种。接地方式的选择在很大程度上取决于变电站所接电网的特点。在选择过程中还需要考虑各种中性点接地方式的优缺点,从技术和经济的角度寻找最佳解决方案。本文以110/ 20kv“布哥依诺”变电站为例,讨论了接地方式对单相短路故障特征的影响。在EMTP-RV软件中对所考虑的变电站、输配电线路进行建模和仿真。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Power Transformer Neutral Point Grounding Methods: Analysis of Fault Characteristics
The method of power transformer neutral point grounding is very important for power distribution network operation because it strongly affect the shapes and values of overvoltages and fault currents. Many methods of grounding are used in medium voltage (MV) power distribution networks. The selection of grounding method largely depends on the characteristics of power network connected to the substation. It is also necessary to consider the advantages and disadvantages of various neutral grounding methods during selection process to find the best solution from a technical and economical point of view. The effects of grounding methods on the characteristics of single-phase short circuit fault are discussed in this paper on the example of 110/20 kV substation ′′Bugojno′′. Modeling and simulation of the considered substation, power transmission and distribution lines are implemented in EMTP-RV software.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信