基于单级蒸汽压缩系统的HCFCs、hfc和天然制冷剂在不同工况下的性能分析

Hao-Jie Tang
{"title":"基于单级蒸汽压缩系统的HCFCs、hfc和天然制冷剂在不同工况下的性能分析","authors":"Hao-Jie Tang","doi":"10.25236/ijndes.2022.060207","DOIUrl":null,"url":null,"abstract":": Environmental problems such as the destruction of the ozone layer and global warming force people to choose refrigerants. It has become an inevitable trend to look for refrigerants with low ODP (Ozone Depletion Potential) and GWP (Global Warming Potential) to replace the refrigerants that are harmful to the environment. In addition, we also need to consider the COP (Coefficient Of Performance) and safety of refrigerants. This paper is based on a single-stage vapor compression refrigeration system, The COP of different refrigerants are calculated and analyzed under five different working conditions. After calculation, the COP of R717 is the highest under five working conditions, and its GWP is 0, but its safety level is only B2L.Therefore, it is very difficult to take into account the various properties of refrigerants at the same time. all the","PeriodicalId":188294,"journal":{"name":"International Journal of New Developments in Engineering and Society","volume":"241 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance analysis of HCFCs, HFCs and natural refrigerants under different working conditions based on single-stage vapor compression system\",\"authors\":\"Hao-Jie Tang\",\"doi\":\"10.25236/ijndes.2022.060207\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": Environmental problems such as the destruction of the ozone layer and global warming force people to choose refrigerants. It has become an inevitable trend to look for refrigerants with low ODP (Ozone Depletion Potential) and GWP (Global Warming Potential) to replace the refrigerants that are harmful to the environment. In addition, we also need to consider the COP (Coefficient Of Performance) and safety of refrigerants. This paper is based on a single-stage vapor compression refrigeration system, The COP of different refrigerants are calculated and analyzed under five different working conditions. After calculation, the COP of R717 is the highest under five working conditions, and its GWP is 0, but its safety level is only B2L.Therefore, it is very difficult to take into account the various properties of refrigerants at the same time. all the\",\"PeriodicalId\":188294,\"journal\":{\"name\":\"International Journal of New Developments in Engineering and Society\",\"volume\":\"241 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of New Developments in Engineering and Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25236/ijndes.2022.060207\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of New Developments in Engineering and Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25236/ijndes.2022.060207","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

诸如臭氧层破坏和全球变暖等环境问题迫使人们选择制冷剂。寻找低臭氧消耗潜能值(ODP)和低全球变暖潜能值(GWP)的制冷剂替代对环境有害的制冷剂已成为必然趋势。此外,我们还需要考虑制冷剂的COP(性能系数)和安全性。本文以单级蒸汽压缩制冷系统为研究对象,对不同制冷剂在5种不同工况下的COP进行了计算和分析。经计算,R717在5种工况下COP最高,GWP为0,但其安全等级仅为B2L。因此,同时考虑制冷剂的各种性能是非常困难的。所有的
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance analysis of HCFCs, HFCs and natural refrigerants under different working conditions based on single-stage vapor compression system
: Environmental problems such as the destruction of the ozone layer and global warming force people to choose refrigerants. It has become an inevitable trend to look for refrigerants with low ODP (Ozone Depletion Potential) and GWP (Global Warming Potential) to replace the refrigerants that are harmful to the environment. In addition, we also need to consider the COP (Coefficient Of Performance) and safety of refrigerants. This paper is based on a single-stage vapor compression refrigeration system, The COP of different refrigerants are calculated and analyzed under five different working conditions. After calculation, the COP of R717 is the highest under five working conditions, and its GWP is 0, but its safety level is only B2L.Therefore, it is very difficult to take into account the various properties of refrigerants at the same time. all the
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信