利用身体成分量表的阻抗容积图估计脉搏到达时间

Birutė Paliakaitė, S. Daukantas, A. Sakalauskas, V. Marozas
{"title":"利用身体成分量表的阻抗容积图估计脉搏到达时间","authors":"Birutė Paliakaitė, S. Daukantas, A. Sakalauskas, V. Marozas","doi":"10.1109/SAS.2015.7133577","DOIUrl":null,"url":null,"abstract":"Long-term periodic monitoring of cardiovascular function in unobtrusive way has been a challenge in sensor research lately. This work presents the investigation of the method for pulse arrival time (PAT) estimation using body composition scales. It employs the electrocardiogram and the impedance plethysmogram (IPG) which are recorded from palm and plantar electrodes already integrated into body composition scales. Four subjects were involved in the experiment. The IPG was acquired from a single-foot and foot-to-foot and compared to the reference method - photoplethysmography. The range of correlation coefficient obtained in different methods varied from 0.7 to 0.94 showing that small PAT variations can be tracked using the IPG signals. Such results suggest that body composition scales could be supplemented with additional parameter for the assessment of arterial stiffness. This function will make them truly multi-parametric device for periodic health monitoring at home.","PeriodicalId":384041,"journal":{"name":"2015 IEEE Sensors Applications Symposium (SAS)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Estimation of pulse arrival time using impedance plethysmogram from body composition scales\",\"authors\":\"Birutė Paliakaitė, S. Daukantas, A. Sakalauskas, V. Marozas\",\"doi\":\"10.1109/SAS.2015.7133577\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Long-term periodic monitoring of cardiovascular function in unobtrusive way has been a challenge in sensor research lately. This work presents the investigation of the method for pulse arrival time (PAT) estimation using body composition scales. It employs the electrocardiogram and the impedance plethysmogram (IPG) which are recorded from palm and plantar electrodes already integrated into body composition scales. Four subjects were involved in the experiment. The IPG was acquired from a single-foot and foot-to-foot and compared to the reference method - photoplethysmography. The range of correlation coefficient obtained in different methods varied from 0.7 to 0.94 showing that small PAT variations can be tracked using the IPG signals. Such results suggest that body composition scales could be supplemented with additional parameter for the assessment of arterial stiffness. This function will make them truly multi-parametric device for periodic health monitoring at home.\",\"PeriodicalId\":384041,\"journal\":{\"name\":\"2015 IEEE Sensors Applications Symposium (SAS)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-04-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Sensors Applications Symposium (SAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SAS.2015.7133577\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Sensors Applications Symposium (SAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SAS.2015.7133577","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

长期、定期、不引人注目地监测心血管功能一直是传感器研究的难点。本文提出了一种基于身体成分尺度的脉冲到达时间(PAT)估计方法。它使用的心电图和阻抗体积描记图(IPG)是由手掌和足底电极记录的,已经集成到身体成分量表中。这个实验涉及四个实验对象。通过单足和足对足采集IPG,并与参考方法光容积脉搏波图进行比较。不同方法获得的相关系数范围为0.7 ~ 0.94,表明利用IPG信号可以跟踪PAT的微小变化。这些结果表明,身体成分量表可以补充额外的参数来评估动脉硬度。这一功能将使它们真正成为家庭健康定期监测的多参数设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Estimation of pulse arrival time using impedance plethysmogram from body composition scales
Long-term periodic monitoring of cardiovascular function in unobtrusive way has been a challenge in sensor research lately. This work presents the investigation of the method for pulse arrival time (PAT) estimation using body composition scales. It employs the electrocardiogram and the impedance plethysmogram (IPG) which are recorded from palm and plantar electrodes already integrated into body composition scales. Four subjects were involved in the experiment. The IPG was acquired from a single-foot and foot-to-foot and compared to the reference method - photoplethysmography. The range of correlation coefficient obtained in different methods varied from 0.7 to 0.94 showing that small PAT variations can be tracked using the IPG signals. Such results suggest that body composition scales could be supplemented with additional parameter for the assessment of arterial stiffness. This function will make them truly multi-parametric device for periodic health monitoring at home.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信