用统计学方法评价栓子检测可靠性

D. Kouamé, J. Girault, A. Ouahabi, F. Patat
{"title":"用统计学方法评价栓子检测可靠性","authors":"D. Kouamé, J. Girault, A. Ouahabi, F. Patat","doi":"10.1109/ULTSYM.1999.849301","DOIUrl":null,"url":null,"abstract":"Cerebral emboli detection is a problem of considerable practical importance for monitoring vascular pathologies. If in most practical in vivo or in vitro experiments, big-size emboli detection seems comfortable, small-size emboli detection remains a challenge. The aim of this paper is to evaluate the performances of micro-emboli detections using statistical tools. The authors first introduce for this purpose a specific decision information through Autoregressive (AR) modeling. To overcome the problem of empirical detection threshold choice and quantify the reliability of the emboli detection, the chosen decision information makes it possible to link the threshold with the probability of false alarm (PFA). The authors then extend this approach to classical detection methods based on nonparametric analysis in order to perform comparisons, by using computer simulation of embolic signal. It is shown that reliable detection is not possible by the classical approaches when the Embolus-to-Blood Ratio (EBR) is lower than 10 dB since in this case the PFA is by far above 10%, whereas the authors' approach can detect small-size emboli with EBR as low as 5 dB since the PFA is then below 5%. In vivo measurements are finally performed in order to validate the authors' approach.","PeriodicalId":339424,"journal":{"name":"1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Reliability evaluation of emboli detection using a statistical approach\",\"authors\":\"D. Kouamé, J. Girault, A. Ouahabi, F. Patat\",\"doi\":\"10.1109/ULTSYM.1999.849301\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cerebral emboli detection is a problem of considerable practical importance for monitoring vascular pathologies. If in most practical in vivo or in vitro experiments, big-size emboli detection seems comfortable, small-size emboli detection remains a challenge. The aim of this paper is to evaluate the performances of micro-emboli detections using statistical tools. The authors first introduce for this purpose a specific decision information through Autoregressive (AR) modeling. To overcome the problem of empirical detection threshold choice and quantify the reliability of the emboli detection, the chosen decision information makes it possible to link the threshold with the probability of false alarm (PFA). The authors then extend this approach to classical detection methods based on nonparametric analysis in order to perform comparisons, by using computer simulation of embolic signal. It is shown that reliable detection is not possible by the classical approaches when the Embolus-to-Blood Ratio (EBR) is lower than 10 dB since in this case the PFA is by far above 10%, whereas the authors' approach can detect small-size emboli with EBR as low as 5 dB since the PFA is then below 5%. In vivo measurements are finally performed in order to validate the authors' approach.\",\"PeriodicalId\":339424,\"journal\":{\"name\":\"1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1999.849301\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1999.849301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

脑栓塞检测对血管病理监测具有重要的实际意义。如果在大多数实际的体内或体外实验中,大尺寸的栓子检测似乎是舒适的,小尺寸的栓子检测仍然是一个挑战。本文的目的是利用统计工具评估微栓子检测的性能。为此,作者首先通过自回归(AR)建模引入了一个特定的决策信息。为了克服经验检测阈值选择问题,量化栓子检测的可靠性,选择的决策信息可以将阈值与虚警概率(PFA)联系起来。然后,作者将这种方法扩展到基于非参数分析的经典检测方法,以便通过使用栓塞信号的计算机模拟进行比较。结果表明,当栓子与血比(EBR)低于10 dB时,经典方法无法可靠检测,因为在这种情况下,PFA远高于10%,而作者的方法可以检测到EBR低至5 dB的小尺寸栓子,因为PFA低于5%。为了验证作者的方法,最后进行了体内测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reliability evaluation of emboli detection using a statistical approach
Cerebral emboli detection is a problem of considerable practical importance for monitoring vascular pathologies. If in most practical in vivo or in vitro experiments, big-size emboli detection seems comfortable, small-size emboli detection remains a challenge. The aim of this paper is to evaluate the performances of micro-emboli detections using statistical tools. The authors first introduce for this purpose a specific decision information through Autoregressive (AR) modeling. To overcome the problem of empirical detection threshold choice and quantify the reliability of the emboli detection, the chosen decision information makes it possible to link the threshold with the probability of false alarm (PFA). The authors then extend this approach to classical detection methods based on nonparametric analysis in order to perform comparisons, by using computer simulation of embolic signal. It is shown that reliable detection is not possible by the classical approaches when the Embolus-to-Blood Ratio (EBR) is lower than 10 dB since in this case the PFA is by far above 10%, whereas the authors' approach can detect small-size emboli with EBR as low as 5 dB since the PFA is then below 5%. In vivo measurements are finally performed in order to validate the authors' approach.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信