单机自励感应发电机的电压和频率调节

G. Dastagir, L. Lopes
{"title":"单机自励感应发电机的电压和频率调节","authors":"G. Dastagir, L. Lopes","doi":"10.1109/EPC.2007.4520383","DOIUrl":null,"url":null,"abstract":"This paper discusses the regulation of the voltage and frequency of a stand-alone self-excited squirrel-cage induction generator (SEIG) connected to an unregulated prime mover by means of a single voltage source inverter (VSI) connected in shunt with the stator of the generator. A battery bank is used at the dc side of the VSI so that it can deal active and reactive power and affect the frequency and magnitude of the generated voltage. The focus of this paper is on the experimental results obtained for a 4-pole 2 HP SEIG with an unregulated prime- mover with a linear torque versus speed characteristic typical of impulse type hydro turbines. It shows that active and reactive power control yields a better voltage and frequency regulation to load variations than reactive power alone.","PeriodicalId":196861,"journal":{"name":"2007 IEEE Canada Electrical Power Conference","volume":"17 12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":"{\"title\":\"Voltage and Frequency Regulation of a Stand-Alone Self-Excited Induction Generator\",\"authors\":\"G. Dastagir, L. Lopes\",\"doi\":\"10.1109/EPC.2007.4520383\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses the regulation of the voltage and frequency of a stand-alone self-excited squirrel-cage induction generator (SEIG) connected to an unregulated prime mover by means of a single voltage source inverter (VSI) connected in shunt with the stator of the generator. A battery bank is used at the dc side of the VSI so that it can deal active and reactive power and affect the frequency and magnitude of the generated voltage. The focus of this paper is on the experimental results obtained for a 4-pole 2 HP SEIG with an unregulated prime- mover with a linear torque versus speed characteristic typical of impulse type hydro turbines. It shows that active and reactive power control yields a better voltage and frequency regulation to load variations than reactive power alone.\",\"PeriodicalId\":196861,\"journal\":{\"name\":\"2007 IEEE Canada Electrical Power Conference\",\"volume\":\"17 12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"23\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Canada Electrical Power Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPC.2007.4520383\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Canada Electrical Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPC.2007.4520383","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

摘要

本文讨论了用与发电机定子并联的单电压源逆变器(VSI)来调节与无调原动机相连的独立自激鼠笼式感应发电机(SEIG)的电压和频率。在VSI的直流侧使用电池组,以便它可以处理有功和无功功率,并影响产生电压的频率和幅度。本文的重点是对具有线性转矩与速度特征的脉冲型水轮机的四极2马力无调原动机SEIG的实验结果进行了研究。结果表明,有功和无功控制对负荷变化的电压和频率调节效果优于无功控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Voltage and Frequency Regulation of a Stand-Alone Self-Excited Induction Generator
This paper discusses the regulation of the voltage and frequency of a stand-alone self-excited squirrel-cage induction generator (SEIG) connected to an unregulated prime mover by means of a single voltage source inverter (VSI) connected in shunt with the stator of the generator. A battery bank is used at the dc side of the VSI so that it can deal active and reactive power and affect the frequency and magnitude of the generated voltage. The focus of this paper is on the experimental results obtained for a 4-pole 2 HP SEIG with an unregulated prime- mover with a linear torque versus speed characteristic typical of impulse type hydro turbines. It shows that active and reactive power control yields a better voltage and frequency regulation to load variations than reactive power alone.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信