某环境传感器站测量频率降低误差评估

Obiora Sam Ezeora, J. Heckenbergerova, P. Musílek, P. Krömer
{"title":"某环境传感器站测量频率降低误差评估","authors":"Obiora Sam Ezeora, J. Heckenbergerova, P. Musílek, P. Krömer","doi":"10.1109/INCoS.2015.44","DOIUrl":null,"url":null,"abstract":"It has become evident that for low-power design concept to be realized, modules within the system need to be optimized. Consequently, the sensor node architecture also known as sensor station is required to operate in an optimized manner to help contribute in reduction of total power consumption of the system. Photosynthetically active radiation (PAR) data obtainedin a Brazilian field study were used to investigate the errors in measurements that would have been missed if sampling time of PAR variable was increased from 5 minutes upto 30 minutes. This is required, not only to help reduce of energy consumption of the sensor station but also to help facilitate the integration of lower frequency bands of industrial scientific and medical (ISM) into the system. Results obtained indicate that daytime PAR variable should be sampled and logged every 20 minutes while longer sampling time may be used during the night-time. Daytime sampling of 30 minutes interval is not recommended.","PeriodicalId":345650,"journal":{"name":"2015 International Conference on Intelligent Networking and Collaborative Systems","volume":"102 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Evaluation of Errors Caused by Lowering Frequency of Measurements of an Environmental Sensor Station\",\"authors\":\"Obiora Sam Ezeora, J. Heckenbergerova, P. Musílek, P. Krömer\",\"doi\":\"10.1109/INCoS.2015.44\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It has become evident that for low-power design concept to be realized, modules within the system need to be optimized. Consequently, the sensor node architecture also known as sensor station is required to operate in an optimized manner to help contribute in reduction of total power consumption of the system. Photosynthetically active radiation (PAR) data obtainedin a Brazilian field study were used to investigate the errors in measurements that would have been missed if sampling time of PAR variable was increased from 5 minutes upto 30 minutes. This is required, not only to help reduce of energy consumption of the sensor station but also to help facilitate the integration of lower frequency bands of industrial scientific and medical (ISM) into the system. Results obtained indicate that daytime PAR variable should be sampled and logged every 20 minutes while longer sampling time may be used during the night-time. Daytime sampling of 30 minutes interval is not recommended.\",\"PeriodicalId\":345650,\"journal\":{\"name\":\"2015 International Conference on Intelligent Networking and Collaborative Systems\",\"volume\":\"102 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Intelligent Networking and Collaborative Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INCoS.2015.44\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Intelligent Networking and Collaborative Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INCoS.2015.44","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

显然,要实现低功耗设计理念,需要对系统内的模块进行优化。因此,传感器节点架构也被称为传感器站,需要以优化的方式运行,以帮助减少系统的总功耗。利用在巴西实地研究中获得的光合有效辐射(PAR)数据,研究了将PAR变量的采样时间从5分钟增加到30分钟所遗漏的测量误差。这不仅有助于降低传感器站的能耗,而且有助于促进将工业科学和医疗(ISM)的较低频段集成到系统中。结果表明,白天PAR变量应每20分钟采样和记录一次,而夜间采样时间可延长。不建议使用间隔30分钟的白天采样。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Errors Caused by Lowering Frequency of Measurements of an Environmental Sensor Station
It has become evident that for low-power design concept to be realized, modules within the system need to be optimized. Consequently, the sensor node architecture also known as sensor station is required to operate in an optimized manner to help contribute in reduction of total power consumption of the system. Photosynthetically active radiation (PAR) data obtainedin a Brazilian field study were used to investigate the errors in measurements that would have been missed if sampling time of PAR variable was increased from 5 minutes upto 30 minutes. This is required, not only to help reduce of energy consumption of the sensor station but also to help facilitate the integration of lower frequency bands of industrial scientific and medical (ISM) into the system. Results obtained indicate that daytime PAR variable should be sampled and logged every 20 minutes while longer sampling time may be used during the night-time. Daytime sampling of 30 minutes interval is not recommended.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信