Defne Us, Amalia Moreno-Galera, S. Nazari-Farsani, K. Palovuori, Heikki Kosola, Tiziana Zedda, U. Ruotsalainen
{"title":"AvanTomography:一个紧凑的模块,用于正电子发射乳房x线摄影","authors":"Defne Us, Amalia Moreno-Galera, S. Nazari-Farsani, K. Palovuori, Heikki Kosola, Tiziana Zedda, U. Ruotsalainen","doi":"10.1109/MeMeA.2015.7145171","DOIUrl":null,"url":null,"abstract":"In AvanTomography project, a compact, high performance module was developed for axial positron emission mammography, which can be integrated with X-ray mammography. With its axial crystal orientation, AvanTomography can achieve a uniform spatial resolution and eliminate the parallax error by unambiguously detecting the location of the positron annihilation. Compact design of the module enables a cost and space efficient system for breast screening. Various configurations, plate or full ring, can be obtained by using multiple modules, allowing the screening of axillary and mammary regions with a single scanner position. In this project, a 6-module system was constructed and tested with a 22Na point source. Energy calibration was performed and initial measurements for energy resolution were conducted.","PeriodicalId":277757,"journal":{"name":"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"AvanTomography: A compact module for positron emission mammography\",\"authors\":\"Defne Us, Amalia Moreno-Galera, S. Nazari-Farsani, K. Palovuori, Heikki Kosola, Tiziana Zedda, U. Ruotsalainen\",\"doi\":\"10.1109/MeMeA.2015.7145171\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In AvanTomography project, a compact, high performance module was developed for axial positron emission mammography, which can be integrated with X-ray mammography. With its axial crystal orientation, AvanTomography can achieve a uniform spatial resolution and eliminate the parallax error by unambiguously detecting the location of the positron annihilation. Compact design of the module enables a cost and space efficient system for breast screening. Various configurations, plate or full ring, can be obtained by using multiple modules, allowing the screening of axillary and mammary regions with a single scanner position. In this project, a 6-module system was constructed and tested with a 22Na point source. Energy calibration was performed and initial measurements for energy resolution were conducted.\",\"PeriodicalId\":277757,\"journal\":{\"name\":\"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA.2015.7145171\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2015.7145171","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
AvanTomography: A compact module for positron emission mammography
In AvanTomography project, a compact, high performance module was developed for axial positron emission mammography, which can be integrated with X-ray mammography. With its axial crystal orientation, AvanTomography can achieve a uniform spatial resolution and eliminate the parallax error by unambiguously detecting the location of the positron annihilation. Compact design of the module enables a cost and space efficient system for breast screening. Various configurations, plate or full ring, can be obtained by using multiple modules, allowing the screening of axillary and mammary regions with a single scanner position. In this project, a 6-module system was constructed and tested with a 22Na point source. Energy calibration was performed and initial measurements for energy resolution were conducted.