Kokuryo Hiroshi, T. Horiguchi, N. Ishikawa, Hori Kengo, Y. Sonoda
{"title":"套筒支撑钢管梁的受力性能研究","authors":"Kokuryo Hiroshi, T. Horiguchi, N. Ishikawa, Hori Kengo, Y. Sonoda","doi":"10.13101/IJECE.13.64","DOIUrl":null,"url":null,"abstract":"A new plane grid-type dam has been recently developed to entrap debris flows including driftwoods. A new plane grid-type dam supported by sleeve pipes is proposed by connecting with concrete buttresses. The advantages of this dam are rapid construction, low maintenance costs and enhanced stability. However, the load-carrying capacity of this dam has not been clarified yet so far. To this end, the load-carrying capacity of a steel pipe beam supported by sleeve pipes is first investigated experimentally. Second, the FEM analysis is performed to estimate the load performance which was not measured by the test. Finally, a new design expression is proposed to evaluate the load-carrying capacity of a steel pipe beam mounted in sleeve pipes.","PeriodicalId":378771,"journal":{"name":"International Journal of Erosion Control Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Study of the Load Performance of a Steel Pipe Beam Supported by Sleeve Pipes\",\"authors\":\"Kokuryo Hiroshi, T. Horiguchi, N. Ishikawa, Hori Kengo, Y. Sonoda\",\"doi\":\"10.13101/IJECE.13.64\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new plane grid-type dam has been recently developed to entrap debris flows including driftwoods. A new plane grid-type dam supported by sleeve pipes is proposed by connecting with concrete buttresses. The advantages of this dam are rapid construction, low maintenance costs and enhanced stability. However, the load-carrying capacity of this dam has not been clarified yet so far. To this end, the load-carrying capacity of a steel pipe beam supported by sleeve pipes is first investigated experimentally. Second, the FEM analysis is performed to estimate the load performance which was not measured by the test. Finally, a new design expression is proposed to evaluate the load-carrying capacity of a steel pipe beam mounted in sleeve pipes.\",\"PeriodicalId\":378771,\"journal\":{\"name\":\"International Journal of Erosion Control Engineering\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Erosion Control Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.13101/IJECE.13.64\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Erosion Control Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13101/IJECE.13.64","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Study of the Load Performance of a Steel Pipe Beam Supported by Sleeve Pipes
A new plane grid-type dam has been recently developed to entrap debris flows including driftwoods. A new plane grid-type dam supported by sleeve pipes is proposed by connecting with concrete buttresses. The advantages of this dam are rapid construction, low maintenance costs and enhanced stability. However, the load-carrying capacity of this dam has not been clarified yet so far. To this end, the load-carrying capacity of a steel pipe beam supported by sleeve pipes is first investigated experimentally. Second, the FEM analysis is performed to estimate the load performance which was not measured by the test. Finally, a new design expression is proposed to evaluate the load-carrying capacity of a steel pipe beam mounted in sleeve pipes.