白细胞酯酶作为尿培养结果的预测因子

W. Rieker, E. Reilly, Balamurugan Pandiyan, S. Lom, A. Merry
{"title":"白细胞酯酶作为尿培养结果的预测因子","authors":"W. Rieker, E. Reilly, Balamurugan Pandiyan, S. Lom, A. Merry","doi":"10.4172/2161-0703.1000264","DOIUrl":null,"url":null,"abstract":"Objective: Assess varying levels of leukocyte esterase presence on urine dipstick as a risk factor for positive urine culture. \nMaterials and methods: Retrospective evaluation of outpatient laboratory data from Beloit Memorial Hospital obtained randomly from samples in outpatient settings in the year 2016. 2000 urine results obtained from automated urine dipstick and microscopy analysis. From the 2000 samples, 1123 patients randomly selected and grouped into controls and case participants based on positive urine cultures. Information gathered included age and gender. \nConclusion: Leukocyte esterase on dipstick analysis at “large” or “moderate” levels are both independent positive predictors of positive urine culture. “Small” level of leukocyte esterase has no predictive value for positive urine culture and “trace” leukocyte level has a negative predictive value for a positive urine culture.","PeriodicalId":269971,"journal":{"name":"Journal of Medical Microbiology and Diagnosis","volume":"135 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Leukocyte Esterase as Predictor of Urine Culture Result\",\"authors\":\"W. Rieker, E. Reilly, Balamurugan Pandiyan, S. Lom, A. Merry\",\"doi\":\"10.4172/2161-0703.1000264\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: Assess varying levels of leukocyte esterase presence on urine dipstick as a risk factor for positive urine culture. \\nMaterials and methods: Retrospective evaluation of outpatient laboratory data from Beloit Memorial Hospital obtained randomly from samples in outpatient settings in the year 2016. 2000 urine results obtained from automated urine dipstick and microscopy analysis. From the 2000 samples, 1123 patients randomly selected and grouped into controls and case participants based on positive urine cultures. Information gathered included age and gender. \\nConclusion: Leukocyte esterase on dipstick analysis at “large” or “moderate” levels are both independent positive predictors of positive urine culture. “Small” level of leukocyte esterase has no predictive value for positive urine culture and “trace” leukocyte level has a negative predictive value for a positive urine culture.\",\"PeriodicalId\":269971,\"journal\":{\"name\":\"Journal of Medical Microbiology and Diagnosis\",\"volume\":\"135 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Microbiology and Diagnosis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4172/2161-0703.1000264\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Microbiology and Diagnosis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2161-0703.1000264","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估尿试纸上不同水平的白细胞酯酶存在作为尿培养阳性的危险因素。材料与方法:回顾性评价2016年Beloit纪念医院门诊实验室数据,随机抽取门诊样本。用自动尿试纸和显微镜分析获得2000例尿液结果。从2000个样本中,随机选择1123名患者,并根据尿培养阳性分组为对照组和病例参与者。收集的信息包括年龄和性别。结论:白细胞酯酶在“大”或“中等”水平的试纸分析都是尿培养阳性的独立阳性预测因子。“小”水平的白细胞酯酶对尿培养阳性没有预测价值,“微量”白细胞水平对尿培养阳性有阴性预测价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Leukocyte Esterase as Predictor of Urine Culture Result
Objective: Assess varying levels of leukocyte esterase presence on urine dipstick as a risk factor for positive urine culture. Materials and methods: Retrospective evaluation of outpatient laboratory data from Beloit Memorial Hospital obtained randomly from samples in outpatient settings in the year 2016. 2000 urine results obtained from automated urine dipstick and microscopy analysis. From the 2000 samples, 1123 patients randomly selected and grouped into controls and case participants based on positive urine cultures. Information gathered included age and gender. Conclusion: Leukocyte esterase on dipstick analysis at “large” or “moderate” levels are both independent positive predictors of positive urine culture. “Small” level of leukocyte esterase has no predictive value for positive urine culture and “trace” leukocyte level has a negative predictive value for a positive urine culture.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信