发生火灾时设备断电

N. Korbel, N. Tullius
{"title":"发生火灾时设备断电","authors":"N. Korbel, N. Tullius","doi":"10.1109/INTLEC.1990.171261","DOIUrl":null,"url":null,"abstract":"The authors present the findings of a study conducted in 1989 to determine viable alternatives for removing power from telecommunication equipment under emergency conditions such as fire in the equipment area. After reviewing the characteristics of commercial fire alarm system, the essential requirements for a fire alarm and emergency powerdown system are discussed. These include fire detection, power shutdown, selectivity, reliability and security, and some cost considerations. A system comprising hydrogen chloride detectors and a novel multiplex sampling method is proposed to attain fast response with reasonable complexity. It is concluded that while the hardware and software building blocks for implementing selective powerdown are available, further work would be required to understand the complex trade-offs between service protection and equipment protection.<<ETX>>","PeriodicalId":264940,"journal":{"name":"12th International Conference on Telecommunications Energy","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1990-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Equipment powerdown in case of fire\",\"authors\":\"N. Korbel, N. Tullius\",\"doi\":\"10.1109/INTLEC.1990.171261\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors present the findings of a study conducted in 1989 to determine viable alternatives for removing power from telecommunication equipment under emergency conditions such as fire in the equipment area. After reviewing the characteristics of commercial fire alarm system, the essential requirements for a fire alarm and emergency powerdown system are discussed. These include fire detection, power shutdown, selectivity, reliability and security, and some cost considerations. A system comprising hydrogen chloride detectors and a novel multiplex sampling method is proposed to attain fast response with reasonable complexity. It is concluded that while the hardware and software building blocks for implementing selective powerdown are available, further work would be required to understand the complex trade-offs between service protection and equipment protection.<<ETX>>\",\"PeriodicalId\":264940,\"journal\":{\"name\":\"12th International Conference on Telecommunications Energy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"12th International Conference on Telecommunications Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTLEC.1990.171261\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"12th International Conference on Telecommunications Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1990.171261","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

提交人介绍了1989年进行的一项研究的结果,该研究旨在确定在设备区发生火灾等紧急情况下从电信设备中撤除电力的可行替代办法。在回顾了商用火灾报警系统的特点后,讨论了火灾报警和紧急断电系统的基本要求。其中包括火灾探测、电源关闭、选择性、可靠性和安全性,以及一些成本考虑。为了在合理的复杂度下获得快速响应,提出了一种由氯化氢探测器和一种新的多重采样方法组成的系统。结论是,虽然实现选择性断电的硬件和软件构建模块是可用的,但还需要进一步的工作来了解服务保护和设备保护之间的复杂权衡。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Equipment powerdown in case of fire
The authors present the findings of a study conducted in 1989 to determine viable alternatives for removing power from telecommunication equipment under emergency conditions such as fire in the equipment area. After reviewing the characteristics of commercial fire alarm system, the essential requirements for a fire alarm and emergency powerdown system are discussed. These include fire detection, power shutdown, selectivity, reliability and security, and some cost considerations. A system comprising hydrogen chloride detectors and a novel multiplex sampling method is proposed to attain fast response with reasonable complexity. It is concluded that while the hardware and software building blocks for implementing selective powerdown are available, further work would be required to understand the complex trade-offs between service protection and equipment protection.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信