在吉隆坡和雪兰莪选定地区暴露在厨房环境中的刨花板的螺丝固定损坏和螺丝保持性能

F. Abu, Mansur Ahmad
{"title":"在吉隆坡和雪兰莪选定地区暴露在厨房环境中的刨花板的螺丝固定损坏和螺丝保持性能","authors":"F. Abu, Mansur Ahmad","doi":"10.1109/ISESEE.2011.5977094","DOIUrl":null,"url":null,"abstract":"Particleboard being the main building material for kitchen cabinet in Malaysia houses has shown some installation problems. The damages observed during installation are in the form of split holes, loose holes and delamination. Almost all of the sites visited have shown some damages of the particleboard during the screw fixing activities. Screw-holding performance test was done in the same condition checked at the selected site. The medium-class to upper-class residential building in Malaysia is generally equipped with air-conditioning units in order to provide thermal comfort to its occupants. It is usually limited to living room, dining room and bedroom. However, kitchens are sometimes being controlled thermally with air-conditioning units and thus are included as the material conditioning in this study. In collaboration with Signature Kitchen Sdn. Bhd., twenty-eight (28) houses in Kuala Lumpur and Selangor selected were monitored and recorded for its average temperature and relative humidity (RH). The particleboards for the screw-holding performance tests were set to an air-conditioned room environment (20°C and 65% RH) and on-site environment (31.3°C and 72% RH). The screw-holding performance test were done on the face and edge surface. It was found that the properties have passed the European Standard (EN). It is concluded that the damages during installation was not cause by the kitchen environmental condition or the quality of particleboard.","PeriodicalId":105476,"journal":{"name":"2011 3rd International Symposium & Exhibition in Sustainable Energy & Environment (ISESEE)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Screw-fixing damages and screw-holding performance in particleboard exposed to the kitchen environment in the selected area of Kuala Lumpur and Selangor\",\"authors\":\"F. Abu, Mansur Ahmad\",\"doi\":\"10.1109/ISESEE.2011.5977094\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Particleboard being the main building material for kitchen cabinet in Malaysia houses has shown some installation problems. The damages observed during installation are in the form of split holes, loose holes and delamination. Almost all of the sites visited have shown some damages of the particleboard during the screw fixing activities. Screw-holding performance test was done in the same condition checked at the selected site. The medium-class to upper-class residential building in Malaysia is generally equipped with air-conditioning units in order to provide thermal comfort to its occupants. It is usually limited to living room, dining room and bedroom. However, kitchens are sometimes being controlled thermally with air-conditioning units and thus are included as the material conditioning in this study. In collaboration with Signature Kitchen Sdn. Bhd., twenty-eight (28) houses in Kuala Lumpur and Selangor selected were monitored and recorded for its average temperature and relative humidity (RH). The particleboards for the screw-holding performance tests were set to an air-conditioned room environment (20°C and 65% RH) and on-site environment (31.3°C and 72% RH). The screw-holding performance test were done on the face and edge surface. It was found that the properties have passed the European Standard (EN). It is concluded that the damages during installation was not cause by the kitchen environmental condition or the quality of particleboard.\",\"PeriodicalId\":105476,\"journal\":{\"name\":\"2011 3rd International Symposium & Exhibition in Sustainable Energy & Environment (ISESEE)\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 3rd International Symposium & Exhibition in Sustainable Energy & Environment (ISESEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISESEE.2011.5977094\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 3rd International Symposium & Exhibition in Sustainable Energy & Environment (ISESEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISESEE.2011.5977094","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

刨花板作为马来西亚家庭厨房橱柜的主要建筑材料,在安装上出现了一些问题。在安装过程中观察到的损伤形式为裂孔、松孔和分层。几乎所有的现场都显示出在螺丝固定过程中刨花板有一定的损坏。在选定的场地,在相同的条件下进行了持螺丝性能试验。马来西亚的中上层住宅建筑一般都配备了空调机组,以便为居住者提供热舒适。通常仅限于客厅、餐厅和卧室。然而,厨房有时是用空调装置进行热控制的,因此被列为本研究的材料调节。与Signature Kitchen Sdn合作。有限公司研究人员对吉隆坡和雪兰莪州选定的28所房屋进行了平均温度和相对湿度(RH)监测和记录。抓钉性能试验的刨花板分别设置在空调室内环境(20℃、65% RH)和现场环境(31.3℃、72% RH)下。在表面和边缘表面进行了螺杆持紧性能试验。经检测,其性能已通过欧洲标准(EN)。结果表明,安装过程中造成的损伤与厨房环境和刨花板质量无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Screw-fixing damages and screw-holding performance in particleboard exposed to the kitchen environment in the selected area of Kuala Lumpur and Selangor
Particleboard being the main building material for kitchen cabinet in Malaysia houses has shown some installation problems. The damages observed during installation are in the form of split holes, loose holes and delamination. Almost all of the sites visited have shown some damages of the particleboard during the screw fixing activities. Screw-holding performance test was done in the same condition checked at the selected site. The medium-class to upper-class residential building in Malaysia is generally equipped with air-conditioning units in order to provide thermal comfort to its occupants. It is usually limited to living room, dining room and bedroom. However, kitchens are sometimes being controlled thermally with air-conditioning units and thus are included as the material conditioning in this study. In collaboration with Signature Kitchen Sdn. Bhd., twenty-eight (28) houses in Kuala Lumpur and Selangor selected were monitored and recorded for its average temperature and relative humidity (RH). The particleboards for the screw-holding performance tests were set to an air-conditioned room environment (20°C and 65% RH) and on-site environment (31.3°C and 72% RH). The screw-holding performance test were done on the face and edge surface. It was found that the properties have passed the European Standard (EN). It is concluded that the damages during installation was not cause by the kitchen environmental condition or the quality of particleboard.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信