{"title":"保护研究的逆变器建模技术","authors":"T. Wijnhoven, J. Tant, Geert Deconinck","doi":"10.1109/PEDG.2012.6253999","DOIUrl":null,"url":null,"abstract":"Traditional fault calculation techniques are not capable of accurately modelling the short-circuit behaviour of inverter interfaced distributed generation (IIDG). As the share of IIDG continues to rise, more accurate fault simulations are required. This paper gives an overview of fault calculation techniques described in literature. All techniques are evaluated from the viewpoint of protection studies in medium and low voltage grids with a high share of IIDG. The averaged value modelling technique is selected. The merits of this technique are illustrated in a Simulink/PLECS simulation environment, where averaged value models are compared to full time-domain switched models in terms of simulation time and accuracy.","PeriodicalId":146438,"journal":{"name":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Inverter modelling techniques for protection studies\",\"authors\":\"T. Wijnhoven, J. Tant, Geert Deconinck\",\"doi\":\"10.1109/PEDG.2012.6253999\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Traditional fault calculation techniques are not capable of accurately modelling the short-circuit behaviour of inverter interfaced distributed generation (IIDG). As the share of IIDG continues to rise, more accurate fault simulations are required. This paper gives an overview of fault calculation techniques described in literature. All techniques are evaluated from the viewpoint of protection studies in medium and low voltage grids with a high share of IIDG. The averaged value modelling technique is selected. The merits of this technique are illustrated in a Simulink/PLECS simulation environment, where averaged value models are compared to full time-domain switched models in terms of simulation time and accuracy.\",\"PeriodicalId\":146438,\"journal\":{\"name\":\"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDG.2012.6253999\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDG.2012.6253999","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

传统的故障计算技术不能准确地模拟逆变器接口分布式发电系统的短路行为。随着IIDG的份额不断上升,需要更精确的故障模拟。本文概述了文献中描述的故障计算技术。所有的技术都是从高IIDG份额的中低压电网的保护研究的角度来评估的。选择平均值建模技术。该技术的优点在Simulink/PLECS仿真环境中得到了说明,在仿真时间和精度方面,将平均值模型与全时域切换模型进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Inverter modelling techniques for protection studies
Traditional fault calculation techniques are not capable of accurately modelling the short-circuit behaviour of inverter interfaced distributed generation (IIDG). As the share of IIDG continues to rise, more accurate fault simulations are required. This paper gives an overview of fault calculation techniques described in literature. All techniques are evaluated from the viewpoint of protection studies in medium and low voltage grids with a high share of IIDG. The averaged value modelling technique is selected. The merits of this technique are illustrated in a Simulink/PLECS simulation environment, where averaged value models are compared to full time-domain switched models in terms of simulation time and accuracy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信