T. Stevens, F. Rogiers, S. Delport, P. Vleugels, J. Peirs, M. Baelmans
{"title":"微型热交换器的集热器压力损失","authors":"T. Stevens, F. Rogiers, S. Delport, P. Vleugels, J. Peirs, M. Baelmans","doi":"10.1109/THETA.2007.363402","DOIUrl":null,"url":null,"abstract":"As collector losses are expected to play a crucial role in micro heat exchangers, an experimental method is developed to determine these losses. Experiments are performed on a micro heat exchanger consisting of 42 parallel microchannels positioned in a 6 by 7 matrix, with hydraulic diameters in the range of 260-280 mum. The proposed method is successfully applied. From the experimental results it can be concluded that the pressure drop of a small collector performs according to classical correlations. However, in a wider collector design the pressure drop clearly deviates from macro scale behaviour","PeriodicalId":346940,"journal":{"name":"2007 International Conference on Thermal Issues in Emerging Technologies: Theory and Application","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Collector Pressure Losses in Micro Heat Exchangers\",\"authors\":\"T. Stevens, F. Rogiers, S. Delport, P. Vleugels, J. Peirs, M. Baelmans\",\"doi\":\"10.1109/THETA.2007.363402\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As collector losses are expected to play a crucial role in micro heat exchangers, an experimental method is developed to determine these losses. Experiments are performed on a micro heat exchanger consisting of 42 parallel microchannels positioned in a 6 by 7 matrix, with hydraulic diameters in the range of 260-280 mum. The proposed method is successfully applied. From the experimental results it can be concluded that the pressure drop of a small collector performs according to classical correlations. However, in a wider collector design the pressure drop clearly deviates from macro scale behaviour\",\"PeriodicalId\":346940,\"journal\":{\"name\":\"2007 International Conference on Thermal Issues in Emerging Technologies: Theory and Application\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 International Conference on Thermal Issues in Emerging Technologies: Theory and Application\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/THETA.2007.363402\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 International Conference on Thermal Issues in Emerging Technologies: Theory and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/THETA.2007.363402","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Collector Pressure Losses in Micro Heat Exchangers
As collector losses are expected to play a crucial role in micro heat exchangers, an experimental method is developed to determine these losses. Experiments are performed on a micro heat exchanger consisting of 42 parallel microchannels positioned in a 6 by 7 matrix, with hydraulic diameters in the range of 260-280 mum. The proposed method is successfully applied. From the experimental results it can be concluded that the pressure drop of a small collector performs according to classical correlations. However, in a wider collector design the pressure drop clearly deviates from macro scale behaviour