G. W. Hooft, M. B. V. D. Mark, J. Hoogenraad, S. Colak, J. Paasschens, E. S. V. D. Linden
{"title":"女性乳房的体内光学成像","authors":"G. W. Hooft, M. B. V. D. Mark, J. Hoogenraad, S. Colak, J. Paasschens, E. S. V. D. Linden","doi":"10.1109/CLEOE.1998.718886","DOIUrl":null,"url":null,"abstract":"Due to its non-ionizing nature, optical mammography could be a very attractive alternative to X-ray screening. We have developed a CW optical tomography apparatus with which three-dimensional images of breasts can be obtained in vivo. It measures the attenuation coefficient \nκ=3μ\n a\n μ\n s\n ' of the breast tissue. The magnitude of the reduced scattering coefficient \nμ\n s\n ' in breast tissue is approximately 1 mm-1 and varies less than the absorption coefficient μ\n a\n .","PeriodicalId":404067,"journal":{"name":"CLEO/Europe Conference on Lasers and Electro-Optics","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In Vivo Optical Imaging of the Female Breast\",\"authors\":\"G. W. Hooft, M. B. V. D. Mark, J. Hoogenraad, S. Colak, J. Paasschens, E. S. V. D. Linden\",\"doi\":\"10.1109/CLEOE.1998.718886\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Due to its non-ionizing nature, optical mammography could be a very attractive alternative to X-ray screening. We have developed a CW optical tomography apparatus with which three-dimensional images of breasts can be obtained in vivo. It measures the attenuation coefficient \\nκ=3μ\\n a\\n μ\\n s\\n ' of the breast tissue. The magnitude of the reduced scattering coefficient \\nμ\\n s\\n ' in breast tissue is approximately 1 mm-1 and varies less than the absorption coefficient μ\\n a\\n .\",\"PeriodicalId\":404067,\"journal\":{\"name\":\"CLEO/Europe Conference on Lasers and Electro-Optics\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CLEO/Europe Conference on Lasers and Electro-Optics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CLEOE.1998.718886\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CLEO/Europe Conference on Lasers and Electro-Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CLEOE.1998.718886","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
由于其非电离性,光学乳房x光摄影可能是x射线筛查的一个非常有吸引力的替代方案。我们开发了一种连续波光学断层扫描设备,可以在体内获得乳房的三维图像。测量乳腺组织的衰减系数κ=3μ a μ s '。乳房组织中散射系数的减小幅度约为1 mm-1,其变化幅度小于吸收系数μ a。
Due to its non-ionizing nature, optical mammography could be a very attractive alternative to X-ray screening. We have developed a CW optical tomography apparatus with which three-dimensional images of breasts can be obtained in vivo. It measures the attenuation coefficient
κ=3μ
a
μ
s
' of the breast tissue. The magnitude of the reduced scattering coefficient
μ
s
' in breast tissue is approximately 1 mm-1 and varies less than the absorption coefficient μ
a
.