盲文出版物凹线易识别点距和线距的评价

Yuto Yamaguchi, Takumi Nanko, K. Doi, T. Nishimura, H. Fujimoto
{"title":"盲文出版物凹线易识别点距和线距的评价","authors":"Yuto Yamaguchi, Takumi Nanko, K. Doi, T. Nishimura, H. Fujimoto","doi":"10.5057/jjske.tjske-d-21-00012","DOIUrl":null,"url":null,"abstract":": In addition to convex dots and lines, concave dots and lines are used for ruled lines in figures and graphs in Braille publications such as in books and textbooks. However, no academic basis for the ease of distinguishing concave dots and lines in Braille publications. Therefore, quantitative guidelines of easy-to-identify concave dots and lines for people with visual impairments are required. In this study, we focused on ruled lines consisting of concave dots and lines, often used in Braille publications, and evaluated dot and line distances to quantitatively determine the identification of concave ruled lines. We found that a narrower concave point interval, such as 2 mm, was more easily identified. Conversely, narrow concave lines, with a line distance of approximately 4–7 mm, were more difficult to identify.","PeriodicalId":127268,"journal":{"name":"Transactions of Japan Society of Kansei Engineering","volume":"255 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Easily Identifiable Dot Distance and Line Distance for Concave Lines Used in Braille Publications\",\"authors\":\"Yuto Yamaguchi, Takumi Nanko, K. Doi, T. Nishimura, H. Fujimoto\",\"doi\":\"10.5057/jjske.tjske-d-21-00012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": In addition to convex dots and lines, concave dots and lines are used for ruled lines in figures and graphs in Braille publications such as in books and textbooks. However, no academic basis for the ease of distinguishing concave dots and lines in Braille publications. Therefore, quantitative guidelines of easy-to-identify concave dots and lines for people with visual impairments are required. In this study, we focused on ruled lines consisting of concave dots and lines, often used in Braille publications, and evaluated dot and line distances to quantitatively determine the identification of concave ruled lines. We found that a narrower concave point interval, such as 2 mm, was more easily identified. Conversely, narrow concave lines, with a line distance of approximately 4–7 mm, were more difficult to identify.\",\"PeriodicalId\":127268,\"journal\":{\"name\":\"Transactions of Japan Society of Kansei Engineering\",\"volume\":\"255 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions of Japan Society of Kansei Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5057/jjske.tjske-d-21-00012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of Japan Society of Kansei Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5057/jjske.tjske-d-21-00012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

:除凸点、凸线外,凹点、凹线在书籍、教科书等盲文出版物的图形和图形中也用作横线。然而,对于盲文出版物中凹点和凹线的容易区分,尚无学术依据。因此,需要为视障人士提供易于识别的凹点和凹线的定量指南。在本研究中,我们重点研究了盲文出版物中经常使用的由凹点和凹线组成的直纹线,并评估了点和线的距离,以定量确定凹直纹线的识别。我们发现,较窄的凹点间隔,如2毫米,更容易识别。相反,线距约为4-7 mm的窄凹线更难识别。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Easily Identifiable Dot Distance and Line Distance for Concave Lines Used in Braille Publications
: In addition to convex dots and lines, concave dots and lines are used for ruled lines in figures and graphs in Braille publications such as in books and textbooks. However, no academic basis for the ease of distinguishing concave dots and lines in Braille publications. Therefore, quantitative guidelines of easy-to-identify concave dots and lines for people with visual impairments are required. In this study, we focused on ruled lines consisting of concave dots and lines, often used in Braille publications, and evaluated dot and line distances to quantitatively determine the identification of concave ruled lines. We found that a narrower concave point interval, such as 2 mm, was more easily identified. Conversely, narrow concave lines, with a line distance of approximately 4–7 mm, were more difficult to identify.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信