{"title":"盖滑处理和安装介质分配可靠的自动盖滑大组织切片","authors":"Hari Narayanan, Sudhan Chandrasekaran, Jayaraman Kiruthi Vasan, Ramdayalan Kumarasami, M. Sivaprakasam, J. Joseph","doi":"10.1109/MeMeA57477.2023.10171950","DOIUrl":null,"url":null,"abstract":"Good quality cover slipping is essential for a reliable histopathological diagnosis and achieving this requires precise placement of the cover glass or cover slip over the tissue specimen mounted on a glass slide, without forming air bubbles. However, manual cover slipping relies heavily on the expertise of the histologist and can be time-consuming, while commercially available automated cover-slippers are limited to handling only 1” x 3” slides suitable for small tissue sizes. For large tissue sections extracted from brain, liver, and other organs, handling large-format slides, cover slips, and dispensing the optimal amount of mounting media can be challenging. To address this challenge, we developed SLIDE PROTEKT, an automated cover-slipper system that can handle slides of sizes 6” x 8”. The reliability of the system to effectively handle large cover slips and dispense the mounting media was validated and the results are presented in this paper. The cover slip pickup mechanism had an 84% accuracy in picking cover slips without misalignments or deformations. The pressure required to pick and hold the cover slip effectively was found to be 15 kilopascals. For large format 6” x 8” slides, the optimal mounting media volume required was 5 milliliters which the system consistently dispensed with a mean error of 4.2%. The validation results highlight the potential impact of SLIDE PROTEKT in histology, particularly in the reliable cover slipping of large tissue sections extracted from the brain and other organs.","PeriodicalId":191927,"journal":{"name":"2023 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cover slip handling and mounting media dispensation for reliable automated cover slipping of large tissue sections\",\"authors\":\"Hari Narayanan, Sudhan Chandrasekaran, Jayaraman Kiruthi Vasan, Ramdayalan Kumarasami, M. Sivaprakasam, J. Joseph\",\"doi\":\"10.1109/MeMeA57477.2023.10171950\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Good quality cover slipping is essential for a reliable histopathological diagnosis and achieving this requires precise placement of the cover glass or cover slip over the tissue specimen mounted on a glass slide, without forming air bubbles. However, manual cover slipping relies heavily on the expertise of the histologist and can be time-consuming, while commercially available automated cover-slippers are limited to handling only 1” x 3” slides suitable for small tissue sizes. For large tissue sections extracted from brain, liver, and other organs, handling large-format slides, cover slips, and dispensing the optimal amount of mounting media can be challenging. To address this challenge, we developed SLIDE PROTEKT, an automated cover-slipper system that can handle slides of sizes 6” x 8”. The reliability of the system to effectively handle large cover slips and dispense the mounting media was validated and the results are presented in this paper. The cover slip pickup mechanism had an 84% accuracy in picking cover slips without misalignments or deformations. The pressure required to pick and hold the cover slip effectively was found to be 15 kilopascals. For large format 6” x 8” slides, the optimal mounting media volume required was 5 milliliters which the system consistently dispensed with a mean error of 4.2%. The validation results highlight the potential impact of SLIDE PROTEKT in histology, particularly in the reliable cover slipping of large tissue sections extracted from the brain and other organs.\",\"PeriodicalId\":191927,\"journal\":{\"name\":\"2023 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA57477.2023.10171950\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA57477.2023.10171950","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

高质量的覆盖滑动对于可靠的组织病理学诊断至关重要,实现这一目标需要精确地放置覆盖玻璃或覆盖滑动在安装在玻璃载玻片上的组织标本上,而不形成气泡。然而,手动滑盖在很大程度上依赖于组织学家的专业知识,并且可能很耗时,而市售的自动滑盖拖鞋仅限于处理适合小组织尺寸的1“x 3”滑块。对于从大脑、肝脏和其他器官中提取的大型组织切片,处理大幅面载玻片、盖玻片和分配最佳数量的安装介质可能具有挑战性。为了应对这一挑战,我们开发了SLIDE PROTEKT,这是一种自动覆盖滑靴系统,可以处理6英寸x 8英寸的滑靴。验证了该系统有效处理大型盖卡瓦和分配安装介质的可靠性,并给出了结果。盖卡瓦拾取机构在拾取盖卡瓦时具有84%的精度,没有错位或变形。有效地拾取和握住盖板卡瓦所需的压力为15千帕斯卡。对于大尺寸6“x 8”载玻片,所需的最佳安装介质体积为5毫升,系统始终可以省去平均误差为4.2%。验证结果强调了SLIDE PROTEKT在组织学上的潜在影响,特别是在从大脑和其他器官中提取的大组织切片的可靠覆盖滑动方面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cover slip handling and mounting media dispensation for reliable automated cover slipping of large tissue sections
Good quality cover slipping is essential for a reliable histopathological diagnosis and achieving this requires precise placement of the cover glass or cover slip over the tissue specimen mounted on a glass slide, without forming air bubbles. However, manual cover slipping relies heavily on the expertise of the histologist and can be time-consuming, while commercially available automated cover-slippers are limited to handling only 1” x 3” slides suitable for small tissue sizes. For large tissue sections extracted from brain, liver, and other organs, handling large-format slides, cover slips, and dispensing the optimal amount of mounting media can be challenging. To address this challenge, we developed SLIDE PROTEKT, an automated cover-slipper system that can handle slides of sizes 6” x 8”. The reliability of the system to effectively handle large cover slips and dispense the mounting media was validated and the results are presented in this paper. The cover slip pickup mechanism had an 84% accuracy in picking cover slips without misalignments or deformations. The pressure required to pick and hold the cover slip effectively was found to be 15 kilopascals. For large format 6” x 8” slides, the optimal mounting media volume required was 5 milliliters which the system consistently dispensed with a mean error of 4.2%. The validation results highlight the potential impact of SLIDE PROTEKT in histology, particularly in the reliable cover slipping of large tissue sections extracted from the brain and other organs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信