市电连接三级NPC逆变系统的虚拟磁链直接功率控制

L. Serpa, J. Kolar
{"title":"市电连接三级NPC逆变系统的虚拟磁链直接功率控制","authors":"L. Serpa, J. Kolar","doi":"10.1541/IEEJIAS.128.491","DOIUrl":null,"url":null,"abstract":"This paper proposes a control strategy which extends the virtual-flux direct power control traditionally employed for the conventional two-level VSI to a three-level NPC inverter. This topology generates a higher number of output voltage levels, increasing the flexibility for selecting an appropriate voltage vector. The mid-point potential is controlled according to the direction of the mid-point current and the sign of the mid-point voltage deviation. The method is adapted to be used with an LCL output filter, where some undesirable characteristics, such as filter resonance, have to be compensated. Further investigation concerning the dependency of the mid-point voltage with the current phase-shift is given. Theoretical analysis is presented and the performance of the proposed method is verified by simulation.","PeriodicalId":325362,"journal":{"name":"2007 Power Conversion Conference - Nagoya","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":"{\"title\":\"Virtual-Flux Direct Power Control for Mains Connected Three-Level NPC Inverter Systems\",\"authors\":\"L. Serpa, J. Kolar\",\"doi\":\"10.1541/IEEJIAS.128.491\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a control strategy which extends the virtual-flux direct power control traditionally employed for the conventional two-level VSI to a three-level NPC inverter. This topology generates a higher number of output voltage levels, increasing the flexibility for selecting an appropriate voltage vector. The mid-point potential is controlled according to the direction of the mid-point current and the sign of the mid-point voltage deviation. The method is adapted to be used with an LCL output filter, where some undesirable characteristics, such as filter resonance, have to be compensated. Further investigation concerning the dependency of the mid-point voltage with the current phase-shift is given. Theoretical analysis is presented and the performance of the proposed method is verified by simulation.\",\"PeriodicalId\":325362,\"journal\":{\"name\":\"2007 Power Conversion Conference - Nagoya\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 Power Conversion Conference - Nagoya\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1541/IEEJIAS.128.491\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Power Conversion Conference - Nagoya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1541/IEEJIAS.128.491","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

摘要

本文提出了一种控制策略,将传统的二电平VSI采用的虚拟磁链直接功率控制扩展到三电平NPC逆变器。这种拓扑结构产生更多的输出电压电平,增加了选择适当电压矢量的灵活性。根据中点电流的方向和中点电压偏差的符号来控制中点电位。该方法适用于LCL输出滤波器,其中一些不希望的特性,如滤波器谐振,必须进行补偿。进一步研究了中点电压与电流相移的关系。对该方法进行了理论分析,并通过仿真验证了其性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Virtual-Flux Direct Power Control for Mains Connected Three-Level NPC Inverter Systems
This paper proposes a control strategy which extends the virtual-flux direct power control traditionally employed for the conventional two-level VSI to a three-level NPC inverter. This topology generates a higher number of output voltage levels, increasing the flexibility for selecting an appropriate voltage vector. The mid-point potential is controlled according to the direction of the mid-point current and the sign of the mid-point voltage deviation. The method is adapted to be used with an LCL output filter, where some undesirable characteristics, such as filter resonance, have to be compensated. Further investigation concerning the dependency of the mid-point voltage with the current phase-shift is given. Theoretical analysis is presented and the performance of the proposed method is verified by simulation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信