Juhyun Lee, N. Jen, Fei Yu, W. Dai, Hongyu Yu, T. Hsiai
{"title":"柔性血管内热传感器评估动脉粥样硬化介导的血流动力学变化","authors":"Juhyun Lee, N. Jen, Fei Yu, W. Dai, Hongyu Yu, T. Hsiai","doi":"10.1109/PAHCE.2012.6233431","DOIUrl":null,"url":null,"abstract":"In this study, we introduced an in vivo convective heat transfer-based micro-electromechanical system (MEMS) sensor that measured real-time experimental vascular shear stress values in the aortas of New Zealand White rabbits (n=4). Experiments were performed to measure flow profile changes in response to hyper-cholesterol diet and an irregular tachycardia condition. We have shown that these conditions induce shear stress changes indicative of pre-atherosclerosis regions by the MEMS thermal sensor.","PeriodicalId":255935,"journal":{"name":"2012 Pan American Health Care Exchanges","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Flexible intravascular thermal sensors to assess atherosclerosis-mediated changes in hemodynamics\",\"authors\":\"Juhyun Lee, N. Jen, Fei Yu, W. Dai, Hongyu Yu, T. Hsiai\",\"doi\":\"10.1109/PAHCE.2012.6233431\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, we introduced an in vivo convective heat transfer-based micro-electromechanical system (MEMS) sensor that measured real-time experimental vascular shear stress values in the aortas of New Zealand White rabbits (n=4). Experiments were performed to measure flow profile changes in response to hyper-cholesterol diet and an irregular tachycardia condition. We have shown that these conditions induce shear stress changes indicative of pre-atherosclerosis regions by the MEMS thermal sensor.\",\"PeriodicalId\":255935,\"journal\":{\"name\":\"2012 Pan American Health Care Exchanges\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-03-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Pan American Health Care Exchanges\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PAHCE.2012.6233431\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Pan American Health Care Exchanges","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAHCE.2012.6233431","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Flexible intravascular thermal sensors to assess atherosclerosis-mediated changes in hemodynamics
In this study, we introduced an in vivo convective heat transfer-based micro-electromechanical system (MEMS) sensor that measured real-time experimental vascular shear stress values in the aortas of New Zealand White rabbits (n=4). Experiments were performed to measure flow profile changes in response to hyper-cholesterol diet and an irregular tachycardia condition. We have shown that these conditions induce shear stress changes indicative of pre-atherosclerosis regions by the MEMS thermal sensor.