非对称非正弦模式下电网振荡功率的评估

M. Burbelo, O. V. Stepura, Vinnytsia Ukraine Itc Energy Accounting Ltd.
{"title":"非对称非正弦模式下电网振荡功率的评估","authors":"M. Burbelo, O. V. Stepura, Vinnytsia Ukraine Itc Energy Accounting Ltd.","doi":"10.31649/1997-9266-2019-142-1-24-30","DOIUrl":null,"url":null,"abstract":"The possibility of detection and evaluation of the influence of distortion sources (asymmetry and higher harmonics) on the quality of electricity of three-phase networks using instantaneous conditional capacities of the reverse and zero sequences is analyzed. Such sources are nonlinear consumers, whose share in total load increases year by year. Nonlinear consumers consume active power at the main frequency and at the same time generate power to the higher harmonics in the network. Significantly in low voltage networks, there is also a share of consumers with asymmetric load of phases. On the basis of the theory of instantaneous power, instantaneous values are allocated on the basis of which informative values can be formed that allow characterizing the influence of nonlinear and asymmetric consumers on deterioration of the quality of electricity, as well as assessing the inefficiency of the distribution network of the electricity supplying organization. \nTo evaluate the impact of nonlinear and asymmetric consumers, it is expedient to use instantaneous conditional capacities  and , which are essentially the product of instantaneous direct current voltage on the current of the reverse and zero sequence, and to assess the fault of the electricity supply organization, which consists in the ineffective construction of the distribution network — instant conditional capacities  and , which is essentially a product of instantaneous current of direct sequence on the back and zero sequence voltage. The formation of these values is carried out using the system of α, β, 0-coordinates, which greatly simplifies the construction of measuring devices. \nIn the presence of harmonic distortions, the RMS values of conditional capacities  and  grow and make up from one to ten percent relatively to the main power generated by the voltage and current of the main frequency of the direct sequence. In the case of load asymmetry, the average values of these quantities increase. At the same time an increase  and testifies to the lack of power of power transformers and the inappropriate use of transformers with the scheme of winding connection \"star / star with zero sequence\" for powering nonlinear consumers.","PeriodicalId":101869,"journal":{"name":"Visnyk of Vinnytsia Politechnical Institute","volume":"151 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the Oscillating Power in Asymmetrical Non-Sinusoidal Modes of Electric Networks\",\"authors\":\"M. Burbelo, O. V. Stepura, Vinnytsia Ukraine Itc Energy Accounting Ltd.\",\"doi\":\"10.31649/1997-9266-2019-142-1-24-30\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The possibility of detection and evaluation of the influence of distortion sources (asymmetry and higher harmonics) on the quality of electricity of three-phase networks using instantaneous conditional capacities of the reverse and zero sequences is analyzed. Such sources are nonlinear consumers, whose share in total load increases year by year. Nonlinear consumers consume active power at the main frequency and at the same time generate power to the higher harmonics in the network. Significantly in low voltage networks, there is also a share of consumers with asymmetric load of phases. On the basis of the theory of instantaneous power, instantaneous values are allocated on the basis of which informative values can be formed that allow characterizing the influence of nonlinear and asymmetric consumers on deterioration of the quality of electricity, as well as assessing the inefficiency of the distribution network of the electricity supplying organization. \\nTo evaluate the impact of nonlinear and asymmetric consumers, it is expedient to use instantaneous conditional capacities  and , which are essentially the product of instantaneous direct current voltage on the current of the reverse and zero sequence, and to assess the fault of the electricity supply organization, which consists in the ineffective construction of the distribution network — instant conditional capacities  and , which is essentially a product of instantaneous current of direct sequence on the back and zero sequence voltage. The formation of these values is carried out using the system of α, β, 0-coordinates, which greatly simplifies the construction of measuring devices. \\nIn the presence of harmonic distortions, the RMS values of conditional capacities  and  grow and make up from one to ten percent relatively to the main power generated by the voltage and current of the main frequency of the direct sequence. In the case of load asymmetry, the average values of these quantities increase. At the same time an increase  and testifies to the lack of power of power transformers and the inappropriate use of transformers with the scheme of winding connection \\\"star / star with zero sequence\\\" for powering nonlinear consumers.\",\"PeriodicalId\":101869,\"journal\":{\"name\":\"Visnyk of Vinnytsia Politechnical Institute\",\"volume\":\"151 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Visnyk of Vinnytsia Politechnical Institute\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31649/1997-9266-2019-142-1-24-30\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Visnyk of Vinnytsia Politechnical Institute","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31649/1997-9266-2019-142-1-24-30","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

分析了利用反向和零序的瞬时条件容量检测和评估三相电网畸变源(不对称和高次谐波)对电能质量影响的可能性。这类源是非线性用户,在总负荷中所占比重逐年增加。非线性用户在消耗主频有功功率的同时,又向电网中产生高次谐波的电力。值得注意的是,在低压电网中,也有一部分用户具有不对称的相位负荷。在瞬时功率理论的基础上,分配瞬时值,在此基础上形成信息值,可以表征非线性和不对称消费者对电力质量恶化的影响,以及评估供电组织配电网的低效率。为了评估非线性和不对称用户的影响,可以使用瞬时条件容量和,它本质上是瞬时直流电压对反向和零序电流的乘积,并评估供电组织的故障,主要在于配电网的无效建设-瞬时条件容量和,其本质上是背接直序瞬时电流与零序电压的乘积。这些值的形成采用α、β、0坐标系进行,大大简化了测量装置的构造。在存在谐波畸变的情况下,条件容量和的RMS值相对于直接序列主频率的电压和电流产生的主功率增长并占比从1%到10%。在负载不对称的情况下,这些量的平均值增加。同时也增加了电力变压器的功率不足,证明了“星/星零序”绕组连接方案中变压器对非线性用户供电的不当使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the Oscillating Power in Asymmetrical Non-Sinusoidal Modes of Electric Networks
The possibility of detection and evaluation of the influence of distortion sources (asymmetry and higher harmonics) on the quality of electricity of three-phase networks using instantaneous conditional capacities of the reverse and zero sequences is analyzed. Such sources are nonlinear consumers, whose share in total load increases year by year. Nonlinear consumers consume active power at the main frequency and at the same time generate power to the higher harmonics in the network. Significantly in low voltage networks, there is also a share of consumers with asymmetric load of phases. On the basis of the theory of instantaneous power, instantaneous values are allocated on the basis of which informative values can be formed that allow characterizing the influence of nonlinear and asymmetric consumers on deterioration of the quality of electricity, as well as assessing the inefficiency of the distribution network of the electricity supplying organization. To evaluate the impact of nonlinear and asymmetric consumers, it is expedient to use instantaneous conditional capacities  and , which are essentially the product of instantaneous direct current voltage on the current of the reverse and zero sequence, and to assess the fault of the electricity supply organization, which consists in the ineffective construction of the distribution network — instant conditional capacities  and , which is essentially a product of instantaneous current of direct sequence on the back and zero sequence voltage. The formation of these values is carried out using the system of α, β, 0-coordinates, which greatly simplifies the construction of measuring devices. In the presence of harmonic distortions, the RMS values of conditional capacities  and  grow and make up from one to ten percent relatively to the main power generated by the voltage and current of the main frequency of the direct sequence. In the case of load asymmetry, the average values of these quantities increase. At the same time an increase  and testifies to the lack of power of power transformers and the inappropriate use of transformers with the scheme of winding connection "star / star with zero sequence" for powering nonlinear consumers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信