{"title":"关于“220-Kv”的讨论。南加州爱迪生公司和大约220千伏的输电线路。研究”","authors":"R. Wood","doi":"10.1109/JOAIEE.1922.6593238","DOIUrl":null,"url":null,"abstract":"W. A. Hillebrand: Concerning the experiments on the disconnector switch, with regard to characteristic flash-over and the opening distance and clearance from the ground necessary to prevent the arc from shooting across the gap. Was any effort made to control the direction of flash-over by means of screens or guards which would reduce the gradient between the blade and the clip on the opposite side?","PeriodicalId":268640,"journal":{"name":"Journal of the American Institute of Electrical Engineers","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1922-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Discussion on “220-Kv. transmission of the Southern California Edison company and some 220-Kv. researches”\",\"authors\":\"R. Wood\",\"doi\":\"10.1109/JOAIEE.1922.6593238\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"W. A. Hillebrand: Concerning the experiments on the disconnector switch, with regard to characteristic flash-over and the opening distance and clearance from the ground necessary to prevent the arc from shooting across the gap. Was any effort made to control the direction of flash-over by means of screens or guards which would reduce the gradient between the blade and the clip on the opposite side?\",\"PeriodicalId\":268640,\"journal\":{\"name\":\"Journal of the American Institute of Electrical Engineers\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1922-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Institute of Electrical Engineers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/JOAIEE.1922.6593238\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Institute of Electrical Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/JOAIEE.1922.6593238","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
W. A. Hillebrand:关于隔离开关的实验,关于特性闪过和防止电弧穿过间隙所必需的开路距离和离地间隙。是否有任何努力,以控制闪过的方向,通过屏幕或保护,以减少叶片之间的梯度和夹子在对面?
Discussion on “220-Kv. transmission of the Southern California Edison company and some 220-Kv. researches”
W. A. Hillebrand: Concerning the experiments on the disconnector switch, with regard to characteristic flash-over and the opening distance and clearance from the ground necessary to prevent the arc from shooting across the gap. Was any effort made to control the direction of flash-over by means of screens or guards which would reduce the gradient between the blade and the clip on the opposite side?