0.1 m重铬酸钾溶液组成标准物质的研制。认证标准物质GSO 10992-2017

A. Shimolin, A. Sobina
{"title":"0.1 m重铬酸钾溶液组成标准物质的研制。认证标准物质GSO 10992-2017","authors":"A. Shimolin, A. Sobina","doi":"10.20915/2077-1177-2019-15-2-39-50","DOIUrl":null,"url":null,"abstract":"This paper describes key stages in the development and investigation of a high-precision certified reference material (CRM) for the composition of potassium dichromate solution. The proposed reference material (RM) exhibits metrological traceability to the units of the International System of Units (SI). Not requiring additional preparation before use, the CRM is convenient for use as a titrant in redox titration. The metrological characteristics of the developed CRM were determined by the direct primary method of coulomet-ric titration using the State Primary Standard GET 176. The interval of permissible certified values of the molar concentration of potassium dichromate in the CRM under study is found to vary from 0.098 mol/dm 3 to 0.102 mol/ dm 3 . The relative expanded uncertainty (k = 2) of the certified value ofpotassium dichromate molar concentration is calculated to be 0.024 %, with relative standard uncertainties caused by long-term and short-term instability each being equal to 0.0044 %. The shelf life of the developed CRM is found to be 1 year, provided that storage conditions are ensured. A procedure for measuring the molar concentration ofpotassium dichromate is described, along with the equipment used. A comprehensive uncertainty budget for the measurements is assembled. The developed CRM is included into the State Register of Certified Reference Materials under the number GSO 10992-2017. The CRM can be used for transferring the mass (molar) concentration unit of a component to RMs and chemical reagents via oxidation-reduction reactions; the verification and calibration of measuring instruments (MI), as well as control of metrological characteristics during MI trials including type approval; MI graduation; validation of measurement procedures; control of measurement results when determining the mass (molar) fraction and mass (molar) concentration of components in liquid and solid substances and materials.","PeriodicalId":296769,"journal":{"name":"Reference materials","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a reference material for the composition of 0.1 m potassium dichromate solution. Certified reference material GSO 10992-2017\",\"authors\":\"A. Shimolin, A. Sobina\",\"doi\":\"10.20915/2077-1177-2019-15-2-39-50\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes key stages in the development and investigation of a high-precision certified reference material (CRM) for the composition of potassium dichromate solution. The proposed reference material (RM) exhibits metrological traceability to the units of the International System of Units (SI). Not requiring additional preparation before use, the CRM is convenient for use as a titrant in redox titration. The metrological characteristics of the developed CRM were determined by the direct primary method of coulomet-ric titration using the State Primary Standard GET 176. The interval of permissible certified values of the molar concentration of potassium dichromate in the CRM under study is found to vary from 0.098 mol/dm 3 to 0.102 mol/ dm 3 . The relative expanded uncertainty (k = 2) of the certified value ofpotassium dichromate molar concentration is calculated to be 0.024 %, with relative standard uncertainties caused by long-term and short-term instability each being equal to 0.0044 %. The shelf life of the developed CRM is found to be 1 year, provided that storage conditions are ensured. A procedure for measuring the molar concentration ofpotassium dichromate is described, along with the equipment used. A comprehensive uncertainty budget for the measurements is assembled. The developed CRM is included into the State Register of Certified Reference Materials under the number GSO 10992-2017. The CRM can be used for transferring the mass (molar) concentration unit of a component to RMs and chemical reagents via oxidation-reduction reactions; the verification and calibration of measuring instruments (MI), as well as control of metrological characteristics during MI trials including type approval; MI graduation; validation of measurement procedures; control of measurement results when determining the mass (molar) fraction and mass (molar) concentration of components in liquid and solid substances and materials.\",\"PeriodicalId\":296769,\"journal\":{\"name\":\"Reference materials\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Reference materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20915/2077-1177-2019-15-2-39-50\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reference materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20915/2077-1177-2019-15-2-39-50","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了重铬酸钾溶液组成的高精度认证标准物质(CRM)的研制和研究的关键阶段。提出的参考物质(RM)显示计量溯源到国际单位制(SI)的单位。在使用前不需要额外的准备,CRM方便用作氧化还原滴定的滴定剂。采用国家一级标准GET 176,采用库仑滴定法直接测定了CRM的计量特性。所研究的CRM中重铬酸钾摩尔浓度的允许认证值区间为0.098 mol/dm 3至0.102 mol/dm 3。计算出重铬酸钾摩尔浓度检定值的相对扩展不确定度(k = 2)为0.024%,长期不稳定性和短期不稳定性引起的相对标准不确定度各为0.0044%。在保证储存条件的情况下,开发的CRM的保质期为1年。描述了一种测量重铬酸钾摩尔浓度的方法,以及所使用的设备。编制了测量的综合不确定度预算。开发的CRM已列入国家认证参考物质登记册,编号为GSO 10992-2017。CRM可用于通过氧化还原反应将组分的质量(摩尔)浓度单位传递给rm和化学试剂;测量仪器(MI)的验证和校准,以及在MI试验期间的计量特性控制,包括型式批准;MI毕业;测量程序的验证;测定液体和固体物质和材料中成分的质量(摩尔)分数和质量(摩尔)浓度时测量结果的控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a reference material for the composition of 0.1 m potassium dichromate solution. Certified reference material GSO 10992-2017
This paper describes key stages in the development and investigation of a high-precision certified reference material (CRM) for the composition of potassium dichromate solution. The proposed reference material (RM) exhibits metrological traceability to the units of the International System of Units (SI). Not requiring additional preparation before use, the CRM is convenient for use as a titrant in redox titration. The metrological characteristics of the developed CRM were determined by the direct primary method of coulomet-ric titration using the State Primary Standard GET 176. The interval of permissible certified values of the molar concentration of potassium dichromate in the CRM under study is found to vary from 0.098 mol/dm 3 to 0.102 mol/ dm 3 . The relative expanded uncertainty (k = 2) of the certified value ofpotassium dichromate molar concentration is calculated to be 0.024 %, with relative standard uncertainties caused by long-term and short-term instability each being equal to 0.0044 %. The shelf life of the developed CRM is found to be 1 year, provided that storage conditions are ensured. A procedure for measuring the molar concentration ofpotassium dichromate is described, along with the equipment used. A comprehensive uncertainty budget for the measurements is assembled. The developed CRM is included into the State Register of Certified Reference Materials under the number GSO 10992-2017. The CRM can be used for transferring the mass (molar) concentration unit of a component to RMs and chemical reagents via oxidation-reduction reactions; the verification and calibration of measuring instruments (MI), as well as control of metrological characteristics during MI trials including type approval; MI graduation; validation of measurement procedures; control of measurement results when determining the mass (molar) fraction and mass (molar) concentration of components in liquid and solid substances and materials.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信