A. Greene, Clément Daviller, S. Polakovic, Noah Davis, C. Roche
{"title":"外科医生与半自动软件测量评估肩胛后翻","authors":"A. Greene, Clément Daviller, S. Polakovic, Noah Davis, C. Roche","doi":"10.29007/x2v4","DOIUrl":null,"url":null,"abstract":"Preoperative anatomic measurements in total shoulder arthroplasty (TSA) influence a surgeon’s decision-making process in deciding treatment options for a given patient. Glenoid retroversion is one of the most significant measurements and can be highly subject to intra- and inter-observer variability in measurement technique. This study compares surgeon measured retroversion values to semi-automated software measured retroversion values on the same 1862 computed tomography scans, showing consistent measurements with an average absolute mean error between the two techniques of 3.1 ± 3.6°","PeriodicalId":385854,"journal":{"name":"EPiC Series in Health Sciences","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Surgeon vs. semi-automated software measured assessment of glenoid retroversion\",\"authors\":\"A. Greene, Clément Daviller, S. Polakovic, Noah Davis, C. Roche\",\"doi\":\"10.29007/x2v4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Preoperative anatomic measurements in total shoulder arthroplasty (TSA) influence a surgeon’s decision-making process in deciding treatment options for a given patient. Glenoid retroversion is one of the most significant measurements and can be highly subject to intra- and inter-observer variability in measurement technique. This study compares surgeon measured retroversion values to semi-automated software measured retroversion values on the same 1862 computed tomography scans, showing consistent measurements with an average absolute mean error between the two techniques of 3.1 ± 3.6°\",\"PeriodicalId\":385854,\"journal\":{\"name\":\"EPiC Series in Health Sciences\",\"volume\":\"53 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EPiC Series in Health Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29007/x2v4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EPiC Series in Health Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29007/x2v4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Surgeon vs. semi-automated software measured assessment of glenoid retroversion
Preoperative anatomic measurements in total shoulder arthroplasty (TSA) influence a surgeon’s decision-making process in deciding treatment options for a given patient. Glenoid retroversion is one of the most significant measurements and can be highly subject to intra- and inter-observer variability in measurement technique. This study compares surgeon measured retroversion values to semi-automated software measured retroversion values on the same 1862 computed tomography scans, showing consistent measurements with an average absolute mean error between the two techniques of 3.1 ± 3.6°