AISI 304不锈钢在酸性氯化物溶液中的局部腐蚀

V. Zatkalíková, L. Markovičová, P. Hanusová
{"title":"AISI 304不锈钢在酸性氯化物溶液中的局部腐蚀","authors":"V. Zatkalíková, L. Markovičová, P. Hanusová","doi":"10.2478/cqpi-2019-0036","DOIUrl":null,"url":null,"abstract":"Abstract AISI 304 austenitic stainless steel is recommended and used for various applications in industry, architecture and medicine. Presence of halides in environment evokes a possibility of the local corrosion which limits seriously exploitation of this material in aggressive conditions. The presented paper is focused on the pitting corrosion resistance (“as received” steel surface) in 1M chloride solution (pH=1.2) at a common (20 °C) and an elevated (50 °C) ambient temperatures. 24-hours exposure immersion test (ASTM G48) and cyclic potentiodynamic test (ASTM G61) are used as the independent test methods. The exposure immersion test is carried out with cross-rolled and longitudinally rolled specimens and the effect of direction of rolling on the resistance to pitting is studied.","PeriodicalId":251135,"journal":{"name":"Quality Production Improvement - QPI","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Local Corrosion of AISI 304 Stainless Steel in Acidic Chloride Solution\",\"authors\":\"V. Zatkalíková, L. Markovičová, P. Hanusová\",\"doi\":\"10.2478/cqpi-2019-0036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract AISI 304 austenitic stainless steel is recommended and used for various applications in industry, architecture and medicine. Presence of halides in environment evokes a possibility of the local corrosion which limits seriously exploitation of this material in aggressive conditions. The presented paper is focused on the pitting corrosion resistance (“as received” steel surface) in 1M chloride solution (pH=1.2) at a common (20 °C) and an elevated (50 °C) ambient temperatures. 24-hours exposure immersion test (ASTM G48) and cyclic potentiodynamic test (ASTM G61) are used as the independent test methods. The exposure immersion test is carried out with cross-rolled and longitudinally rolled specimens and the effect of direction of rolling on the resistance to pitting is studied.\",\"PeriodicalId\":251135,\"journal\":{\"name\":\"Quality Production Improvement - QPI\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Quality Production Improvement - QPI\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/cqpi-2019-0036\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quality Production Improvement - QPI","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/cqpi-2019-0036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

AISI 304奥氏体不锈钢被推荐用于工业、建筑和医疗的各种场合。环境中卤化物的存在引起了局部腐蚀的可能性,这严重限制了这种材料在腐蚀性条件下的开发。本文的重点是在普通(20°C)和升高(50°C)的环境温度下,在1M氯化物溶液(pH=1.2)中耐点蚀性(“接收到的”钢表面)。采用24小时浸泡暴露试验(ASTM G48)和循环动电位试验(ASTM G61)作为独立的试验方法。对横轧和纵轧试样进行了暴露浸渍试验,研究了轧制方向对抗点蚀性能的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Local Corrosion of AISI 304 Stainless Steel in Acidic Chloride Solution
Abstract AISI 304 austenitic stainless steel is recommended and used for various applications in industry, architecture and medicine. Presence of halides in environment evokes a possibility of the local corrosion which limits seriously exploitation of this material in aggressive conditions. The presented paper is focused on the pitting corrosion resistance (“as received” steel surface) in 1M chloride solution (pH=1.2) at a common (20 °C) and an elevated (50 °C) ambient temperatures. 24-hours exposure immersion test (ASTM G48) and cyclic potentiodynamic test (ASTM G61) are used as the independent test methods. The exposure immersion test is carried out with cross-rolled and longitudinally rolled specimens and the effect of direction of rolling on the resistance to pitting is studied.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信