{"title":"用非相干核磁共振谱仪研究横向弛豫时间","authors":"M. Pikuła, K. V. Shimko","doi":"10.1109/CAOL.2013.6657646","DOIUrl":null,"url":null,"abstract":"Research of the time of the transverse relaxation T2 using the incoherent NMR-spectrometer and Carr-Purcell sequence. Measurements have shown that this sequence can be used as an estimate of the relaxation time syne the error presents there (~15%).","PeriodicalId":189618,"journal":{"name":"2013 International Conference on Advanced Optoelectronics and Lasers (CAOL 2013)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Research of the time of the transverse relaxation using the incoherent NMR-spectrometer\",\"authors\":\"M. Pikuła, K. V. Shimko\",\"doi\":\"10.1109/CAOL.2013.6657646\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Research of the time of the transverse relaxation T2 using the incoherent NMR-spectrometer and Carr-Purcell sequence. Measurements have shown that this sequence can be used as an estimate of the relaxation time syne the error presents there (~15%).\",\"PeriodicalId\":189618,\"journal\":{\"name\":\"2013 International Conference on Advanced Optoelectronics and Lasers (CAOL 2013)\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 International Conference on Advanced Optoelectronics and Lasers (CAOL 2013)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CAOL.2013.6657646\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Conference on Advanced Optoelectronics and Lasers (CAOL 2013)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CAOL.2013.6657646","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research of the time of the transverse relaxation using the incoherent NMR-spectrometer
Research of the time of the transverse relaxation T2 using the incoherent NMR-spectrometer and Carr-Purcell sequence. Measurements have shown that this sequence can be used as an estimate of the relaxation time syne the error presents there (~15%).