船用高精度GPS导航系统现状

R. G. Welshe, R. Wong, D. Rochester, R. Fischer
{"title":"船用高精度GPS导航系统现状","authors":"R. G. Welshe, R. Wong, D. Rochester, R. Fischer","doi":"10.1109/PLANS.1992.185873","DOIUrl":null,"url":null,"abstract":"Western Geophysical has been developing a proprietary high-precision differential GPS (Global Positioning System) marine navigation system with the goal of providing submeter real-time positioning of a marine seismic survey vessel located up to 1000 km from a land-based reference station. The system measures L1 and L2 group delay observables without knowledge of the P code and uses them to derive the ionospheric corrections. Various land-based tests have been run on a prototype system, demonstrating the capability of obtaining real-time accuracies of 1 m and post-fit submeter absolute accuracies at distances up to 650 km, with average errors consistently less than 0.5 m. Results of the tests are reported.<<ETX>>","PeriodicalId":422101,"journal":{"name":"IEEE PLANS 92 Position Location and Navigation Symposium Record","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Status of marine high-precision GPS navigation system\",\"authors\":\"R. G. Welshe, R. Wong, D. Rochester, R. Fischer\",\"doi\":\"10.1109/PLANS.1992.185873\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Western Geophysical has been developing a proprietary high-precision differential GPS (Global Positioning System) marine navigation system with the goal of providing submeter real-time positioning of a marine seismic survey vessel located up to 1000 km from a land-based reference station. The system measures L1 and L2 group delay observables without knowledge of the P code and uses them to derive the ionospheric corrections. Various land-based tests have been run on a prototype system, demonstrating the capability of obtaining real-time accuracies of 1 m and post-fit submeter absolute accuracies at distances up to 650 km, with average errors consistently less than 0.5 m. Results of the tests are reported.<<ETX>>\",\"PeriodicalId\":422101,\"journal\":{\"name\":\"IEEE PLANS 92 Position Location and Navigation Symposium Record\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE PLANS 92 Position Location and Navigation Symposium Record\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PLANS.1992.185873\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PLANS 92 Position Location and Navigation Symposium Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PLANS.1992.185873","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

西方地球物理公司一直在开发一种专有的高精度差分GPS(全球定位系统)海洋导航系统,其目标是为距离陆基参考站1000公里的海洋地震调查船提供亚米级实时定位。该系统在不知道P码的情况下测量L1和L2群延迟观测值,并利用它们推导电离层修正。在原型系统上进行了各种陆基测试,证明能够在最远650公里的距离上获得1米的实时精度和拟合后亚米的绝对精度,平均误差始终小于0.5米。报告了测试结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Status of marine high-precision GPS navigation system
Western Geophysical has been developing a proprietary high-precision differential GPS (Global Positioning System) marine navigation system with the goal of providing submeter real-time positioning of a marine seismic survey vessel located up to 1000 km from a land-based reference station. The system measures L1 and L2 group delay observables without knowledge of the P code and uses them to derive the ionospheric corrections. Various land-based tests have been run on a prototype system, demonstrating the capability of obtaining real-time accuracies of 1 m and post-fit submeter absolute accuracies at distances up to 650 km, with average errors consistently less than 0.5 m. Results of the tests are reported.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信