广域电网保护的频率监测

J. Ko, Chul-Won Park, Dong-Kwang Shin, Chul-Hwan Kim, Hak-Man Kim, Yoon-Sang Kim
{"title":"广域电网保护的频率监测","authors":"J. Ko, Chul-Won Park, Dong-Kwang Shin, Chul-Hwan Kim, Hak-Man Kim, Yoon-Sang Kim","doi":"10.1109/ICISA.2011.5772386","DOIUrl":null,"url":null,"abstract":"There have been recent research activities on GPS-based FNET to prevent wide-area blackouts by monitoring frequency deviation. This study developed a system for monitoring regional frequencies in power grid modeling as an advanced research project for implementing intelligent wide-area protective relaying. The system was implemented by modeling an actual 345 kV transmission system using EMTP-RV and by measuring voltages and currents at 5 regions. The frequencies were estimated with a frequency estimation algorithm using gain compensation. The monitoring software implemented by this study was used to visualize frequency propagation effects and review simulation processes in various failure conditions.","PeriodicalId":425210,"journal":{"name":"2011 International Conference on Information Science and Applications","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Frequency Monitoring for Wide-Area Power Grid Protection\",\"authors\":\"J. Ko, Chul-Won Park, Dong-Kwang Shin, Chul-Hwan Kim, Hak-Man Kim, Yoon-Sang Kim\",\"doi\":\"10.1109/ICISA.2011.5772386\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There have been recent research activities on GPS-based FNET to prevent wide-area blackouts by monitoring frequency deviation. This study developed a system for monitoring regional frequencies in power grid modeling as an advanced research project for implementing intelligent wide-area protective relaying. The system was implemented by modeling an actual 345 kV transmission system using EMTP-RV and by measuring voltages and currents at 5 regions. The frequencies were estimated with a frequency estimation algorithm using gain compensation. The monitoring software implemented by this study was used to visualize frequency propagation effects and review simulation processes in various failure conditions.\",\"PeriodicalId\":425210,\"journal\":{\"name\":\"2011 International Conference on Information Science and Applications\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-04-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Information Science and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICISA.2011.5772386\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Information Science and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICISA.2011.5772386","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

近年来,人们开展了基于gps的FNET的研究活动,通过监测频率偏差来防止广域停电。本研究开发了电网建模中区域频率监测系统,作为实现智能广域保护继电保护的前沿研究项目。该系统通过使用EMTP-RV对实际345 kV输电系统进行建模,并通过测量5个区域的电压和电流来实现。使用增益补偿的频率估计算法估计频率。利用本研究实现的监测软件可视化频率传播效应,并回顾各种故障条件下的模拟过程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Frequency Monitoring for Wide-Area Power Grid Protection
There have been recent research activities on GPS-based FNET to prevent wide-area blackouts by monitoring frequency deviation. This study developed a system for monitoring regional frequencies in power grid modeling as an advanced research project for implementing intelligent wide-area protective relaying. The system was implemented by modeling an actual 345 kV transmission system using EMTP-RV and by measuring voltages and currents at 5 regions. The frequencies were estimated with a frequency estimation algorithm using gain compensation. The monitoring software implemented by this study was used to visualize frequency propagation effects and review simulation processes in various failure conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信