带LCL滤波器的并网电压源逆变器的数据驱动PI控制

Kamran Moradi, Hêmin Sheikhahmadi, Pourya Zamani, Q. Shafiee, H. Bevrani
{"title":"带LCL滤波器的并网电压源逆变器的数据驱动PI控制","authors":"Kamran Moradi, Hêmin Sheikhahmadi, Pourya Zamani, Q. Shafiee, H. Bevrani","doi":"10.1109/pedstc53976.2022.9767371","DOIUrl":null,"url":null,"abstract":"The complexity of microgrid (MG) control has been a point of contention when implementing an appropriate controller due to factors such as grid distortion, external disturbances, uncertainties, and the inaccessibility of these applications to an exact model. To address this, designers must either reduce the sensitivity and accuracy of control objectives to an acceptable level, which is not always possible, or use more computationally complex controllers. The proportional-integral (PI) controller is the most popular in practice due to its simple and straightforward structure. Numerous algorithms have been presented to well-tune the parameters of this type of controller. The primary difficulty in determining the PI controller coefficients is extracting an accurate model of the studied system. As a result, recent consideration has been given to control methods based on system input/output data measurements. This paper proposes a data-driven method for tuning PI controller coefficients referred to as iterative feedback tuning (IFT) to control the inverter-side current of a three-phase grid-connected voltage source inverter (VSI) under grid distortion and various grid frequency conditions. Simulation results are provided to validate the proposed method.","PeriodicalId":213924,"journal":{"name":"2022 13th Power Electronics, Drive Systems, and Technologies Conference (PEDSTC)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Data-driven PI Control of Grid-Connected Voltage Source Inverters Interfaced with LCL Filter\",\"authors\":\"Kamran Moradi, Hêmin Sheikhahmadi, Pourya Zamani, Q. Shafiee, H. Bevrani\",\"doi\":\"10.1109/pedstc53976.2022.9767371\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The complexity of microgrid (MG) control has been a point of contention when implementing an appropriate controller due to factors such as grid distortion, external disturbances, uncertainties, and the inaccessibility of these applications to an exact model. To address this, designers must either reduce the sensitivity and accuracy of control objectives to an acceptable level, which is not always possible, or use more computationally complex controllers. The proportional-integral (PI) controller is the most popular in practice due to its simple and straightforward structure. Numerous algorithms have been presented to well-tune the parameters of this type of controller. The primary difficulty in determining the PI controller coefficients is extracting an accurate model of the studied system. As a result, recent consideration has been given to control methods based on system input/output data measurements. This paper proposes a data-driven method for tuning PI controller coefficients referred to as iterative feedback tuning (IFT) to control the inverter-side current of a three-phase grid-connected voltage source inverter (VSI) under grid distortion and various grid frequency conditions. Simulation results are provided to validate the proposed method.\",\"PeriodicalId\":213924,\"journal\":{\"name\":\"2022 13th Power Electronics, Drive Systems, and Technologies Conference (PEDSTC)\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 13th Power Electronics, Drive Systems, and Technologies Conference (PEDSTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/pedstc53976.2022.9767371\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 13th Power Electronics, Drive Systems, and Technologies Conference (PEDSTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/pedstc53976.2022.9767371","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于网格畸变、外部干扰、不确定性以及这些应用程序对精确模型的不可访问性等因素,在实现适当的控制器时,微电网(MG)控制的复杂性一直是争论的焦点。为了解决这个问题,设计师必须将控制目标的灵敏度和精度降低到可接受的水平,这并不总是可能的,或者使用更多计算复杂的控制器。比例积分(PI)控制器因其结构简单明了而在实践中最受欢迎。已经提出了许多算法来很好地调整这类控制器的参数。确定PI控制器系数的主要困难是提取所研究系统的精确模型。因此,最近考虑了基于系统输入/输出数据测量的控制方法。本文提出了一种数据驱动的PI控制器系数的迭代反馈调谐(IFT)方法,以控制三相并网电压源逆变器(VSI)在电网畸变和各种电网频率条件下的逆变器侧电流。仿真结果验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Data-driven PI Control of Grid-Connected Voltage Source Inverters Interfaced with LCL Filter
The complexity of microgrid (MG) control has been a point of contention when implementing an appropriate controller due to factors such as grid distortion, external disturbances, uncertainties, and the inaccessibility of these applications to an exact model. To address this, designers must either reduce the sensitivity and accuracy of control objectives to an acceptable level, which is not always possible, or use more computationally complex controllers. The proportional-integral (PI) controller is the most popular in practice due to its simple and straightforward structure. Numerous algorithms have been presented to well-tune the parameters of this type of controller. The primary difficulty in determining the PI controller coefficients is extracting an accurate model of the studied system. As a result, recent consideration has been given to control methods based on system input/output data measurements. This paper proposes a data-driven method for tuning PI controller coefficients referred to as iterative feedback tuning (IFT) to control the inverter-side current of a three-phase grid-connected voltage source inverter (VSI) under grid distortion and various grid frequency conditions. Simulation results are provided to validate the proposed method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信