结构光轮廓仪的柔性立体校准

M. Bevilacqua, G. D. Leo, M. Landi, C. Liguori, V. Paciello, A. Paolillo, A. Pietrosanto
{"title":"结构光轮廓仪的柔性立体校准","authors":"M. Bevilacqua, G. D. Leo, M. Landi, C. Liguori, V. Paciello, A. Paolillo, A. Pietrosanto","doi":"10.1109/ICIT.2013.6505813","DOIUrl":null,"url":null,"abstract":"The paper proposes a novel method for the calibration of a 3-D scanner composed of a camera and a projector. The proposed method models the projector as a second camera, and then reduces the calibration of a camera - projector pair into the calibration of a stereo pair of cameras, with advantages in terms of simplicity, flexibility, accuracy and availability of known solutions. This approach is very advantageous overall for those scanners whose camera and projector can be moved by the operators in order to achieve the most suitable configuration for the specific object under measurement. Results are shown for different organizations of the procedure and for different geometrical configurations. The uncertainty of calibrated parameters is also discussed.","PeriodicalId":192784,"journal":{"name":"2013 IEEE International Conference on Industrial Technology (ICIT)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A flexible stereo calibration for a structured-light profilometer\",\"authors\":\"M. Bevilacqua, G. D. Leo, M. Landi, C. Liguori, V. Paciello, A. Paolillo, A. Pietrosanto\",\"doi\":\"10.1109/ICIT.2013.6505813\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper proposes a novel method for the calibration of a 3-D scanner composed of a camera and a projector. The proposed method models the projector as a second camera, and then reduces the calibration of a camera - projector pair into the calibration of a stereo pair of cameras, with advantages in terms of simplicity, flexibility, accuracy and availability of known solutions. This approach is very advantageous overall for those scanners whose camera and projector can be moved by the operators in order to achieve the most suitable configuration for the specific object under measurement. Results are shown for different organizations of the procedure and for different geometrical configurations. The uncertainty of calibrated parameters is also discussed.\",\"PeriodicalId\":192784,\"journal\":{\"name\":\"2013 IEEE International Conference on Industrial Technology (ICIT)\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Conference on Industrial Technology (ICIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIT.2013.6505813\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Industrial Technology (ICIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2013.6505813","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

提出了一种由摄像机和投影仪组成的三维扫描仪的标定新方法。该方法将投影机建模为第二摄像机,然后将摄像机-投影机对的校准简化为立体摄像机对的校准,具有简单、灵活、准确和已知解决方案可用性等优点。对于那些摄像机和投影仪可以由操作员移动的扫描仪来说,这种方法总体上是非常有利的,以便为测量的特定对象实现最合适的配置。结果显示了不同组织的程序和不同的几何构型。对标定参数的不确定度进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A flexible stereo calibration for a structured-light profilometer
The paper proposes a novel method for the calibration of a 3-D scanner composed of a camera and a projector. The proposed method models the projector as a second camera, and then reduces the calibration of a camera - projector pair into the calibration of a stereo pair of cameras, with advantages in terms of simplicity, flexibility, accuracy and availability of known solutions. This approach is very advantageous overall for those scanners whose camera and projector can be moved by the operators in order to achieve the most suitable configuration for the specific object under measurement. Results are shown for different organizations of the procedure and for different geometrical configurations. The uncertainty of calibrated parameters is also discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信