最便宜的方法来解决闪烁问题

J. Cobben, C. Rong, W. Kling, J. Myrzik
{"title":"最便宜的方法来解决闪烁问题","authors":"J. Cobben, C. Rong, W. Kling, J. Myrzik","doi":"10.1109/UPEC.2006.367639","DOIUrl":null,"url":null,"abstract":"Measurements during the last eight years show an increasing level of PIt, an indicator used for the flicker level. Furthermore, almost 50% of all technical customer complaints are flicker problems. The short-circuit power on the connection point is a very important parameter for controlling the fast voltage variations that lead to flicker. However, a high short circuit level can not be established unless investments in the low voltage grid are made. Analyzing the database of customers complaints shows that in only 25% of all cases the short-circuit power is less than the minimum value given in the national grid code, as indication. So other solutions, without investment in the network, are needed","PeriodicalId":184186,"journal":{"name":"Proceedings of the 41st International Universities Power Engineering Conference","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"The Cheapest Way to Solve the Flicker Problem\",\"authors\":\"J. Cobben, C. Rong, W. Kling, J. Myrzik\",\"doi\":\"10.1109/UPEC.2006.367639\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measurements during the last eight years show an increasing level of PIt, an indicator used for the flicker level. Furthermore, almost 50% of all technical customer complaints are flicker problems. The short-circuit power on the connection point is a very important parameter for controlling the fast voltage variations that lead to flicker. However, a high short circuit level can not be established unless investments in the low voltage grid are made. Analyzing the database of customers complaints shows that in only 25% of all cases the short-circuit power is less than the minimum value given in the national grid code, as indication. So other solutions, without investment in the network, are needed\",\"PeriodicalId\":184186,\"journal\":{\"name\":\"Proceedings of the 41st International Universities Power Engineering Conference\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 41st International Universities Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2006.367639\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 41st International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2006.367639","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

过去八年的测量显示,用于闪烁水平的指示器PIt的水平在增加。此外,几乎50%的技术客户投诉是闪烁问题。连接点上的短路功率是控制电压快速变化导致闪变的重要参数。然而,除非对低压电网进行投资,否则无法建立高短路水平。对客户投诉数据库的分析表明,在所有情况下,只有25%的短路功率小于国家电网代码中给出的最小值。因此,不需要在网络上投资的其他解决方案是必要的
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Cheapest Way to Solve the Flicker Problem
Measurements during the last eight years show an increasing level of PIt, an indicator used for the flicker level. Furthermore, almost 50% of all technical customer complaints are flicker problems. The short-circuit power on the connection point is a very important parameter for controlling the fast voltage variations that lead to flicker. However, a high short circuit level can not be established unless investments in the low voltage grid are made. Analyzing the database of customers complaints shows that in only 25% of all cases the short-circuit power is less than the minimum value given in the national grid code, as indication. So other solutions, without investment in the network, are needed
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信