{"title":"最便宜的方法来解决闪烁问题","authors":"J. Cobben, C. Rong, W. Kling, J. Myrzik","doi":"10.1109/UPEC.2006.367639","DOIUrl":null,"url":null,"abstract":"Measurements during the last eight years show an increasing level of PIt, an indicator used for the flicker level. Furthermore, almost 50% of all technical customer complaints are flicker problems. The short-circuit power on the connection point is a very important parameter for controlling the fast voltage variations that lead to flicker. However, a high short circuit level can not be established unless investments in the low voltage grid are made. Analyzing the database of customers complaints shows that in only 25% of all cases the short-circuit power is less than the minimum value given in the national grid code, as indication. So other solutions, without investment in the network, are needed","PeriodicalId":184186,"journal":{"name":"Proceedings of the 41st International Universities Power Engineering Conference","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"The Cheapest Way to Solve the Flicker Problem\",\"authors\":\"J. Cobben, C. Rong, W. Kling, J. Myrzik\",\"doi\":\"10.1109/UPEC.2006.367639\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measurements during the last eight years show an increasing level of PIt, an indicator used for the flicker level. Furthermore, almost 50% of all technical customer complaints are flicker problems. The short-circuit power on the connection point is a very important parameter for controlling the fast voltage variations that lead to flicker. However, a high short circuit level can not be established unless investments in the low voltage grid are made. Analyzing the database of customers complaints shows that in only 25% of all cases the short-circuit power is less than the minimum value given in the national grid code, as indication. So other solutions, without investment in the network, are needed\",\"PeriodicalId\":184186,\"journal\":{\"name\":\"Proceedings of the 41st International Universities Power Engineering Conference\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 41st International Universities Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2006.367639\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 41st International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2006.367639","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Measurements during the last eight years show an increasing level of PIt, an indicator used for the flicker level. Furthermore, almost 50% of all technical customer complaints are flicker problems. The short-circuit power on the connection point is a very important parameter for controlling the fast voltage variations that lead to flicker. However, a high short circuit level can not be established unless investments in the low voltage grid are made. Analyzing the database of customers complaints shows that in only 25% of all cases the short-circuit power is less than the minimum value given in the national grid code, as indication. So other solutions, without investment in the network, are needed