改变小通道蒸发器形状和尺寸以提高co & _ _ _ _ _ _ _ _ _ _ 2空调循环制冷量的研究

Kimhang Vo, Thanhtrung Dang
{"title":"改变小通道蒸发器形状和尺寸以提高co & _ _ _ _ _ _ _ _ _ _ 2空调循环制冷量的研究","authors":"Kimhang Vo, Thanhtrung Dang","doi":"10.1109/GTSD.2018.8595693","DOIUrl":null,"url":null,"abstract":"An experimental on the change of the shape and size of the minichannel evaporators to increase the cooling capacity of the $CO_{2}$ air conditioning cycle was carried out. Two minichannel evaporators with the same heat transfer area were designed with different channel lengths. In this study, the ambient temperature was tested for both evaporators at $32.5^{o}C$. For both cases, the cooler pressure and evaporator pressure are 77 bar and 42 bar, respectively. The results show that the cooling capacity of the evaporator E2 (shorter length) is 6.6 better than that obtained from the evaporator E1 (longer length): the air outlet temperature of E2 is 1.4 t lower than that of E1. In addition, the temperature distribution of the evaporator E2 is better than that of the evaporator E1. The study also concluded that the COP of the E2 is $\\theta.22$ larger than that obtained from the E1.","PeriodicalId":344653,"journal":{"name":"2018 4th International Conference on Green Technology and Sustainable Development (GTSD)","volume":"167 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Study on Change of the Shape and Size of the Minichannel Evaporators to Enhance the Cooling Capacity of the CO&underscore;2 Air Conditioning Cycle\",\"authors\":\"Kimhang Vo, Thanhtrung Dang\",\"doi\":\"10.1109/GTSD.2018.8595693\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An experimental on the change of the shape and size of the minichannel evaporators to increase the cooling capacity of the $CO_{2}$ air conditioning cycle was carried out. Two minichannel evaporators with the same heat transfer area were designed with different channel lengths. In this study, the ambient temperature was tested for both evaporators at $32.5^{o}C$. For both cases, the cooler pressure and evaporator pressure are 77 bar and 42 bar, respectively. The results show that the cooling capacity of the evaporator E2 (shorter length) is 6.6 better than that obtained from the evaporator E1 (longer length): the air outlet temperature of E2 is 1.4 t lower than that of E1. In addition, the temperature distribution of the evaporator E2 is better than that of the evaporator E1. The study also concluded that the COP of the E2 is $\\\\theta.22$ larger than that obtained from the E1.\",\"PeriodicalId\":344653,\"journal\":{\"name\":\"2018 4th International Conference on Green Technology and Sustainable Development (GTSD)\",\"volume\":\"167 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 4th International Conference on Green Technology and Sustainable Development (GTSD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GTSD.2018.8595693\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 4th International Conference on Green Technology and Sustainable Development (GTSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GTSD.2018.8595693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对改变小通道蒸发器的形状和尺寸以提高$CO_{2}$空调循环的制冷量进行了实验研究。设计了两个换热面积相同、通道长度不同的小通道蒸发器。在本研究中,两个蒸发器的环境温度均为32.5^{0}C。对于这两种情况,冷却器压力和蒸发器压力分别为77bar和42bar。结果表明,长度较短的E2蒸发器的制冷量比长度较长的E1蒸发器的制冷量高6.6 t, E2的出风口温度比E1低1.4 t。此外,蒸发器E2的温度分布优于蒸发器E1。研究还得出E2的COP为$\theta。比从E1获得的多22美元。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Study on Change of the Shape and Size of the Minichannel Evaporators to Enhance the Cooling Capacity of the CO&underscore;2 Air Conditioning Cycle
An experimental on the change of the shape and size of the minichannel evaporators to increase the cooling capacity of the $CO_{2}$ air conditioning cycle was carried out. Two minichannel evaporators with the same heat transfer area were designed with different channel lengths. In this study, the ambient temperature was tested for both evaporators at $32.5^{o}C$. For both cases, the cooler pressure and evaporator pressure are 77 bar and 42 bar, respectively. The results show that the cooling capacity of the evaporator E2 (shorter length) is 6.6 better than that obtained from the evaporator E1 (longer length): the air outlet temperature of E2 is 1.4 t lower than that of E1. In addition, the temperature distribution of the evaporator E2 is better than that of the evaporator E1. The study also concluded that the COP of the E2 is $\theta.22$ larger than that obtained from the E1.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信