{"title":"一种确定配电系统中开关电容器组精确位置的新算法","authors":"H. Khani, M. Moallem, S. Sadri","doi":"10.1109/TD-ASIA.2009.5356977","DOIUrl":null,"url":null,"abstract":"In this paper a novel algorithm is proposed in order to determine the exact location of switched capacitor banks in distribution systems. The method consists of two steps. In the first step, the direction of switched capacitor bank is determined by evaluating power factor changes before and after the switching instant. In the second step, a method based on linear circuit theory is used to estimate the exact distance of switched capacitor bank from monitoring location using existing capacitor switching transient data. The method is valid for both wye and delta configured capacitor banks. The proof of the method is given and then the efficacy of the proposed algorithm is validated using the IEEE 13-bus distribution system.","PeriodicalId":131589,"journal":{"name":"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"A novel algorithm for determining the exact location of switched capacitor banks in distribution systems\",\"authors\":\"H. Khani, M. Moallem, S. Sadri\",\"doi\":\"10.1109/TD-ASIA.2009.5356977\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper a novel algorithm is proposed in order to determine the exact location of switched capacitor banks in distribution systems. The method consists of two steps. In the first step, the direction of switched capacitor bank is determined by evaluating power factor changes before and after the switching instant. In the second step, a method based on linear circuit theory is used to estimate the exact distance of switched capacitor bank from monitoring location using existing capacitor switching transient data. The method is valid for both wye and delta configured capacitor banks. The proof of the method is given and then the efficacy of the proposed algorithm is validated using the IEEE 13-bus distribution system.\",\"PeriodicalId\":131589,\"journal\":{\"name\":\"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TD-ASIA.2009.5356977\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TD-ASIA.2009.5356977","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

为了确定配电系统中开关电容器组的准确位置,本文提出了一种新的算法。该方法包括两个步骤。第一步,通过评估开关时刻前后功率因数的变化来确定开关电容器组的方向。第二步,采用基于线性电路理论的方法,利用已有的电容开关暂态数据估计开关电容组与监测位置的精确距离。该方法适用于楔形和三角形配置电容器组。给出了算法的证明,并用IEEE 13总线配电网验证了算法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel algorithm for determining the exact location of switched capacitor banks in distribution systems
In this paper a novel algorithm is proposed in order to determine the exact location of switched capacitor banks in distribution systems. The method consists of two steps. In the first step, the direction of switched capacitor bank is determined by evaluating power factor changes before and after the switching instant. In the second step, a method based on linear circuit theory is used to estimate the exact distance of switched capacitor bank from monitoring location using existing capacitor switching transient data. The method is valid for both wye and delta configured capacitor banks. The proof of the method is given and then the efficacy of the proposed algorithm is validated using the IEEE 13-bus distribution system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信