基于HLR方法的中电配水管网渗漏检测建模与仿真

K. Gupta, K. Kishore, S. C. Jain
{"title":"基于HLR方法的中电配水管网渗漏检测建模与仿真","authors":"K. Gupta, K. Kishore, S. C. Jain","doi":"10.1109/ICRITO.2017.8342440","DOIUrl":null,"url":null,"abstract":"This paper incorporates water distribution network (WDN) design of CSIR-CEERI, Pilani and then detecting the presence of leakage in it. For design purpose, EPANET computer software is used to execute elongated duration hydraulics and water quality simulation. The analysis results depict possibly generated pressure and flow values at respective nodes and pipes. For leak detection, emitter coefficient is introduced and then, designed network is loaded in MATLAB to apply Head Loss Ratio (HLR) algorithm, a ratio of two differences in nodal pressure values. The plot so generated reveals that pressure value reduces drastically, showing the existence of leakage in the network.","PeriodicalId":357118,"journal":{"name":"2017 6th International Conference on Reliability, Infocom Technologies and Optimization (Trends and Future Directions) (ICRITO)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Modeling and simulation of CEERI's water distribution network to detect leakage using HLR approach\",\"authors\":\"K. Gupta, K. Kishore, S. C. Jain\",\"doi\":\"10.1109/ICRITO.2017.8342440\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper incorporates water distribution network (WDN) design of CSIR-CEERI, Pilani and then detecting the presence of leakage in it. For design purpose, EPANET computer software is used to execute elongated duration hydraulics and water quality simulation. The analysis results depict possibly generated pressure and flow values at respective nodes and pipes. For leak detection, emitter coefficient is introduced and then, designed network is loaded in MATLAB to apply Head Loss Ratio (HLR) algorithm, a ratio of two differences in nodal pressure values. The plot so generated reveals that pressure value reduces drastically, showing the existence of leakage in the network.\",\"PeriodicalId\":357118,\"journal\":{\"name\":\"2017 6th International Conference on Reliability, Infocom Technologies and Optimization (Trends and Future Directions) (ICRITO)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 6th International Conference on Reliability, Infocom Technologies and Optimization (Trends and Future Directions) (ICRITO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICRITO.2017.8342440\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 6th International Conference on Reliability, Infocom Technologies and Optimization (Trends and Future Directions) (ICRITO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICRITO.2017.8342440","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文结合CSIR-CEERI, Pilani供水管网的设计,并对管网中是否存在渗漏进行检测。为了设计目的,使用EPANET计算机软件执行长时间水力和水质模拟。分析结果描述了在各自节点和管道上可能产生的压力和流量值。在泄漏检测方面,首先引入发射器系数,然后在MATLAB中加载设计的网络,应用水头损失比(HLR)算法,即节点压力值的两个差值之比。由此生成的图显示压力值急剧下降,表明网络中存在泄漏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modeling and simulation of CEERI's water distribution network to detect leakage using HLR approach
This paper incorporates water distribution network (WDN) design of CSIR-CEERI, Pilani and then detecting the presence of leakage in it. For design purpose, EPANET computer software is used to execute elongated duration hydraulics and water quality simulation. The analysis results depict possibly generated pressure and flow values at respective nodes and pipes. For leak detection, emitter coefficient is introduced and then, designed network is loaded in MATLAB to apply Head Loss Ratio (HLR) algorithm, a ratio of two differences in nodal pressure values. The plot so generated reveals that pressure value reduces drastically, showing the existence of leakage in the network.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信