混凝土各向异性与浇筑方向的关系评估

L. Kosteski, E. Marangon, J. D. Riera, Fancisco Junior Keche dos Santos, Matthews Vargas Vaucher Bandeira
{"title":"混凝土各向异性与浇筑方向的关系评估","authors":"L. Kosteski, E. Marangon, J. D. Riera, Fancisco Junior Keche dos Santos, Matthews Vargas Vaucher Bandeira","doi":"10.5335/RSAEE.V15I2.7852","DOIUrl":null,"url":null,"abstract":"In numerical predictions of both static and dynamic response of concrete structures, the usual assumption of global isotropic behavior is usually accepted, constituting standard practice in structural analysis and design. It has been recognized, however, that in situ concrete compressive strength of drilled cores in the direction normal to the direction of casting is somewhat smaller than the strength in the vertical direction. Since the consideration of this factor may reduce model error in numerical schemes that assume isotropic behavior, experimental studies were conducted in order to quantify the degree of anisotropy that may be expected in concrete structures. These initial studies suggest that the effect may result in errors as high as 10% in the estimated carrying capacity, deserving in consequence additional research.","PeriodicalId":263272,"journal":{"name":"Revista Sul-americana de Engenharia Estrutural","volume":"295 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"ASSESSMENT OF CONCRETE ANISOTROPY IN RELATION TO THE DIRECTION OF CASTING\",\"authors\":\"L. Kosteski, E. Marangon, J. D. Riera, Fancisco Junior Keche dos Santos, Matthews Vargas Vaucher Bandeira\",\"doi\":\"10.5335/RSAEE.V15I2.7852\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In numerical predictions of both static and dynamic response of concrete structures, the usual assumption of global isotropic behavior is usually accepted, constituting standard practice in structural analysis and design. It has been recognized, however, that in situ concrete compressive strength of drilled cores in the direction normal to the direction of casting is somewhat smaller than the strength in the vertical direction. Since the consideration of this factor may reduce model error in numerical schemes that assume isotropic behavior, experimental studies were conducted in order to quantify the degree of anisotropy that may be expected in concrete structures. These initial studies suggest that the effect may result in errors as high as 10% in the estimated carrying capacity, deserving in consequence additional research.\",\"PeriodicalId\":263272,\"journal\":{\"name\":\"Revista Sul-americana de Engenharia Estrutural\",\"volume\":\"295 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Sul-americana de Engenharia Estrutural\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5335/RSAEE.V15I2.7852\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Sul-americana de Engenharia Estrutural","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5335/RSAEE.V15I2.7852","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

在混凝土结构静力和动力响应的数值预测中,通常接受全局各向同性行为的假设,这是结构分析和设计的标准做法。然而,人们已经认识到,钻孔岩心在浇筑方向法向的原位混凝土抗压强度略小于垂直方向的强度。由于考虑这一因素可以减少假设各向同性行为的数值方案中的模型误差,因此进行了实验研究,以量化混凝土结构中可能预期的各向异性程度。这些初步研究表明,这种影响可能导致估计承载能力的误差高达10%,因此值得进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
ASSESSMENT OF CONCRETE ANISOTROPY IN RELATION TO THE DIRECTION OF CASTING
In numerical predictions of both static and dynamic response of concrete structures, the usual assumption of global isotropic behavior is usually accepted, constituting standard practice in structural analysis and design. It has been recognized, however, that in situ concrete compressive strength of drilled cores in the direction normal to the direction of casting is somewhat smaller than the strength in the vertical direction. Since the consideration of this factor may reduce model error in numerical schemes that assume isotropic behavior, experimental studies were conducted in order to quantify the degree of anisotropy that may be expected in concrete structures. These initial studies suggest that the effect may result in errors as high as 10% in the estimated carrying capacity, deserving in consequence additional research.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信