电气设备火灾危险故障模拟及火灾和电气损害评估

M. Prus, A. V. Perikov
{"title":"电气设备火灾危险故障模拟及火灾和电气损害评估","authors":"M. Prus, A. V. Perikov","doi":"10.25257/tts.2022.3.97.190-201","DOIUrl":null,"url":null,"abstract":"Introduction. The development of fire risk modeling methods seems to be a promising direction for improving the information and analytical support of risk-based management in specialized systems aimed at reducing socio-economic losses from fires by minimizing the flow of incidents generated by the main sources of fire risks. The purpose of the study is to develop new approaches to the study of fire risks arising from the operation of electrical equipment, based on the development of the concept of fire and electrical damage, which is a complex characteristic of the totality of factors affecting the level of fire hazard of the operation of electrical appliances. Methods for stochastic modeling of fire hazardous failures of electrical equipment are based on the representation of the generalized operating time as an integral functional from the main operational factors, including factors determined by the quality of the consumed electricity. Results and discussion. Based on cognitive modeling, the possibilities of influencing the reduction of damage from fires in the residential sector for electrical reasons are considered when using means for monitoring the quality of consumed electricity. A general model of fire-dangerous failures of electrical equipment has been constructed, which describes the occurrence of individual components of fire-electrical damage, due to the influence of the quality of consumed electricity on an accelerated decrease in the fire-safe resource and an increase in the generalized operating time. A technique is proposed for estimating the maximum service life of electrical equipment in the residential sector, based on modeling the achievement of an acceptable level of ignition probability for electrical reasons during a given service life, taking into account the dynamics of indicators of the quality of consumed electricity. Conclusions. The model of fire-hazardous failures can be used as the basis for creating experimental methods for determining the terms of fire-safe operation of electrical equipment, taking into account deviations in power quality indicators from the normative ones. When registering power quality indicators, modeling of fire hazardous failures makes it possible to quantify the components of fire and electrical damage. Identification of the processes and mechanisms of the occurrence of individual components of fire and electrical damage is necessary when designing a system of risk-based management of the quality of consumed electricity and substantiating a system of measures aimed at improving the quality of electricity consumed and reducing the fire hazard of electrical appliances. Keywords: operation of electrical equipment, indicators of the quality of electricity, fire-safe resource, fire-electric damage.","PeriodicalId":356653,"journal":{"name":"Technology of technosphere safety","volume":"178 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simulation of fire dangerous failures of electrical equipment and assessment of fire and electric damage\",\"authors\":\"M. Prus, A. V. Perikov\",\"doi\":\"10.25257/tts.2022.3.97.190-201\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction. The development of fire risk modeling methods seems to be a promising direction for improving the information and analytical support of risk-based management in specialized systems aimed at reducing socio-economic losses from fires by minimizing the flow of incidents generated by the main sources of fire risks. The purpose of the study is to develop new approaches to the study of fire risks arising from the operation of electrical equipment, based on the development of the concept of fire and electrical damage, which is a complex characteristic of the totality of factors affecting the level of fire hazard of the operation of electrical appliances. Methods for stochastic modeling of fire hazardous failures of electrical equipment are based on the representation of the generalized operating time as an integral functional from the main operational factors, including factors determined by the quality of the consumed electricity. Results and discussion. Based on cognitive modeling, the possibilities of influencing the reduction of damage from fires in the residential sector for electrical reasons are considered when using means for monitoring the quality of consumed electricity. A general model of fire-dangerous failures of electrical equipment has been constructed, which describes the occurrence of individual components of fire-electrical damage, due to the influence of the quality of consumed electricity on an accelerated decrease in the fire-safe resource and an increase in the generalized operating time. A technique is proposed for estimating the maximum service life of electrical equipment in the residential sector, based on modeling the achievement of an acceptable level of ignition probability for electrical reasons during a given service life, taking into account the dynamics of indicators of the quality of consumed electricity. Conclusions. The model of fire-hazardous failures can be used as the basis for creating experimental methods for determining the terms of fire-safe operation of electrical equipment, taking into account deviations in power quality indicators from the normative ones. When registering power quality indicators, modeling of fire hazardous failures makes it possible to quantify the components of fire and electrical damage. Identification of the processes and mechanisms of the occurrence of individual components of fire and electrical damage is necessary when designing a system of risk-based management of the quality of consumed electricity and substantiating a system of measures aimed at improving the quality of electricity consumed and reducing the fire hazard of electrical appliances. Keywords: operation of electrical equipment, indicators of the quality of electricity, fire-safe resource, fire-electric damage.\",\"PeriodicalId\":356653,\"journal\":{\"name\":\"Technology of technosphere safety\",\"volume\":\"178 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technology of technosphere safety\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25257/tts.2022.3.97.190-201\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology of technosphere safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25257/tts.2022.3.97.190-201","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍。火险建模方法的发展似乎是一个很有希望的方向,可以改善专门系统中基于风险的管理的信息和分析支持,旨在通过尽量减少主要火险来源产生的事件的流动来减少火灾造成的社会经济损失。这项研究的目的是根据火灾和电气损害概念的发展,开发研究电气设备运行引起的火灾风险的新方法。电气损害是影响电气设备运行的火灾危险程度的综合因素的复杂特征。电气设备火灾危险故障的随机建模方法是基于将广义运行时间表示为主要运行因素的积分函数,包括由消耗的电力质量决定的因素。结果和讨论。基于认知模型,在使用监测所消耗电力质量的手段时,考虑了由于电力原因影响减少住宅部门火灾损害的可能性。建立了电气设备火灾危险故障的通用模型,该模型描述了由于用电质量对火灾安全资源的加速减少和广义运行时间的增加的影响,导致火灾电气损坏的单个部件的发生。提出了一种估算住宅部门电气设备最大使用寿命的技术,该技术基于在给定使用寿命期间实现电气原因的可接受的着火概率水平的建模,同时考虑到消耗电力质量指标的动态。结论。在考虑电能质量指标与规范指标偏差的情况下,火灾危险失效模型可作为制定确定电气设备火灾安全运行条件的实验方法的基础。在登记电能质量指标时,对火灾危险故障进行建模可以量化火灾和电气损坏的组成部分。在设计以风险为基础的用电质量管理系统和制定旨在提高用电质量和减少电器火灾危险的措施系统时,确定发生火灾和电气损害的各个组成部分的过程和机制是必要的。关键词:电气设备运行、用电质量指标、消防安全资源、火电危害
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simulation of fire dangerous failures of electrical equipment and assessment of fire and electric damage
Introduction. The development of fire risk modeling methods seems to be a promising direction for improving the information and analytical support of risk-based management in specialized systems aimed at reducing socio-economic losses from fires by minimizing the flow of incidents generated by the main sources of fire risks. The purpose of the study is to develop new approaches to the study of fire risks arising from the operation of electrical equipment, based on the development of the concept of fire and electrical damage, which is a complex characteristic of the totality of factors affecting the level of fire hazard of the operation of electrical appliances. Methods for stochastic modeling of fire hazardous failures of electrical equipment are based on the representation of the generalized operating time as an integral functional from the main operational factors, including factors determined by the quality of the consumed electricity. Results and discussion. Based on cognitive modeling, the possibilities of influencing the reduction of damage from fires in the residential sector for electrical reasons are considered when using means for monitoring the quality of consumed electricity. A general model of fire-dangerous failures of electrical equipment has been constructed, which describes the occurrence of individual components of fire-electrical damage, due to the influence of the quality of consumed electricity on an accelerated decrease in the fire-safe resource and an increase in the generalized operating time. A technique is proposed for estimating the maximum service life of electrical equipment in the residential sector, based on modeling the achievement of an acceptable level of ignition probability for electrical reasons during a given service life, taking into account the dynamics of indicators of the quality of consumed electricity. Conclusions. The model of fire-hazardous failures can be used as the basis for creating experimental methods for determining the terms of fire-safe operation of electrical equipment, taking into account deviations in power quality indicators from the normative ones. When registering power quality indicators, modeling of fire hazardous failures makes it possible to quantify the components of fire and electrical damage. Identification of the processes and mechanisms of the occurrence of individual components of fire and electrical damage is necessary when designing a system of risk-based management of the quality of consumed electricity and substantiating a system of measures aimed at improving the quality of electricity consumed and reducing the fire hazard of electrical appliances. Keywords: operation of electrical equipment, indicators of the quality of electricity, fire-safe resource, fire-electric damage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信