用于动脉脉搏记录的阵列传感器——减少运动伪影

E. Ciaccio, G. Drzewiecki
{"title":"用于动脉脉搏记录的阵列传感器——减少运动伪影","authors":"E. Ciaccio, G. Drzewiecki","doi":"10.1109/NEBC.1988.19345","DOIUrl":null,"url":null,"abstract":"A linear array of three high sensitivity piezoelectric crystals are spaced 0.75 cm apart and bonded to a plastic block. The crystals are used in the thickness compression mode to measure the pressure pulse. The signal from each crystal is amplified and processed for noise reduction. The array is aligned perpendicular to the artery, and information from the off-axis sensors is averaged and subtracted from the on-axis signal. In addition, the sensors are aligned on-axis for determination of blood velocity from the phase difference between sensors. Experimental results indicate that motion artifact is mostly common-mode and that the contact stress on the surface of the skin is therefore uniform. Preliminary cancellation techniques provided are simple yet effective in restoring disturbed pulse recordings.<<ETX>>","PeriodicalId":165980,"journal":{"name":"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Array sensor for arterial pulse recording-reduction of motion artifact\",\"authors\":\"E. Ciaccio, G. Drzewiecki\",\"doi\":\"10.1109/NEBC.1988.19345\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A linear array of three high sensitivity piezoelectric crystals are spaced 0.75 cm apart and bonded to a plastic block. The crystals are used in the thickness compression mode to measure the pressure pulse. The signal from each crystal is amplified and processed for noise reduction. The array is aligned perpendicular to the artery, and information from the off-axis sensors is averaged and subtracted from the on-axis signal. In addition, the sensors are aligned on-axis for determination of blood velocity from the phase difference between sensors. Experimental results indicate that motion artifact is mostly common-mode and that the contact stress on the surface of the skin is therefore uniform. Preliminary cancellation techniques provided are simple yet effective in restoring disturbed pulse recordings.<<ETX>>\",\"PeriodicalId\":165980,\"journal\":{\"name\":\"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBC.1988.19345\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBC.1988.19345","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

三个高灵敏度压电晶体的线性阵列间隔0.75厘米,并连接到一个塑料块上。晶体在厚度压缩模式下用于测量压力脉冲。来自每个晶体的信号被放大和处理以降低噪声。该阵列垂直于动脉,来自离轴传感器的信息被平均并从轴上信号中减去。此外,传感器在轴上对齐,以便从传感器之间的相位差确定血流速度。实验结果表明,运动伪影大多为共模,因此皮肤表面的接触应力是均匀的。提供的初步消除技术简单而有效地恢复了受干扰的脉冲记录。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Array sensor for arterial pulse recording-reduction of motion artifact
A linear array of three high sensitivity piezoelectric crystals are spaced 0.75 cm apart and bonded to a plastic block. The crystals are used in the thickness compression mode to measure the pressure pulse. The signal from each crystal is amplified and processed for noise reduction. The array is aligned perpendicular to the artery, and information from the off-axis sensors is averaged and subtracted from the on-axis signal. In addition, the sensors are aligned on-axis for determination of blood velocity from the phase difference between sensors. Experimental results indicate that motion artifact is mostly common-mode and that the contact stress on the surface of the skin is therefore uniform. Preliminary cancellation techniques provided are simple yet effective in restoring disturbed pulse recordings.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信