大电流触发真空开关触发特性研究

Ling Dai, Yongxia Han, Fuchang Lin, Hua Li, Lei Wang, Han Zeng, Zhenghao He
{"title":"大电流触发真空开关触发特性研究","authors":"Ling Dai, Yongxia Han, Fuchang Lin, Hua Li, Lei Wang, Han Zeng, Zhenghao He","doi":"10.1109/ELT.2008.83","DOIUrl":null,"url":null,"abstract":"High current switch is a key component of a pulsed power source. Triggered vacuum switch (TVS) possesses many advantages including wide range of operating voltage, compact structure, low cost and so on, so it is considered as one of the most compelling switch in pulsed power system. This paper describes two types (A and B) of TVS samples with different main electrodes and triggering electrodes. Based on theoretical analyis and experimental results, the triggering characteristics of TVS samples have been researched. The triggering polarity, triggering energy and operating voltage influence the triggering delay and the jitter of delay. To recover the failure of TVS samples caused by decreased triggering energy, series air gap was tried. In the lifetime test, the resistance between the triggering electrodes dropped gradually, leading to the failure of TVS. Both types of TVS have discharges number of 100 shots with 70kA peak current. The ablation on the main electrodes of type B TVS was slighter than that of type A.","PeriodicalId":170049,"journal":{"name":"2008 14th Symposium on Electromagnetic Launch Technology","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Study on Triggering Characteristics of High Current Triggered Vacuum Switches\",\"authors\":\"Ling Dai, Yongxia Han, Fuchang Lin, Hua Li, Lei Wang, Han Zeng, Zhenghao He\",\"doi\":\"10.1109/ELT.2008.83\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High current switch is a key component of a pulsed power source. Triggered vacuum switch (TVS) possesses many advantages including wide range of operating voltage, compact structure, low cost and so on, so it is considered as one of the most compelling switch in pulsed power system. This paper describes two types (A and B) of TVS samples with different main electrodes and triggering electrodes. Based on theoretical analyis and experimental results, the triggering characteristics of TVS samples have been researched. The triggering polarity, triggering energy and operating voltage influence the triggering delay and the jitter of delay. To recover the failure of TVS samples caused by decreased triggering energy, series air gap was tried. In the lifetime test, the resistance between the triggering electrodes dropped gradually, leading to the failure of TVS. Both types of TVS have discharges number of 100 shots with 70kA peak current. The ablation on the main electrodes of type B TVS was slighter than that of type A.\",\"PeriodicalId\":170049,\"journal\":{\"name\":\"2008 14th Symposium on Electromagnetic Launch Technology\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 14th Symposium on Electromagnetic Launch Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELT.2008.83\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 14th Symposium on Electromagnetic Launch Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELT.2008.83","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

大电流开关是脉冲电源的关键部件。触发真空开关(TVS)具有工作电压范围宽、结构紧凑、成本低等优点,被认为是脉冲电力系统中最具竞争力的开关之一。本文介绍了具有不同主电极和触发电极的两种TVS样品(A和B)。在理论分析和实验结果的基础上,对TVS样品的触发特性进行了研究。触发极性、触发能量和工作电压影响触发延时和延时抖动。为了恢复触发能量降低导致的TVS样品失效,尝试了串联气隙。在寿命测试中,触发电极之间的电阻逐渐下降,导致TVS失效。两种型号的电视都有放电次数100次,峰值电流为70kA。B型TVS主电极的烧蚀程度较A型轻。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study on Triggering Characteristics of High Current Triggered Vacuum Switches
High current switch is a key component of a pulsed power source. Triggered vacuum switch (TVS) possesses many advantages including wide range of operating voltage, compact structure, low cost and so on, so it is considered as one of the most compelling switch in pulsed power system. This paper describes two types (A and B) of TVS samples with different main electrodes and triggering electrodes. Based on theoretical analyis and experimental results, the triggering characteristics of TVS samples have been researched. The triggering polarity, triggering energy and operating voltage influence the triggering delay and the jitter of delay. To recover the failure of TVS samples caused by decreased triggering energy, series air gap was tried. In the lifetime test, the resistance between the triggering electrodes dropped gradually, leading to the failure of TVS. Both types of TVS have discharges number of 100 shots with 70kA peak current. The ablation on the main electrodes of type B TVS was slighter than that of type A.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信