{"title":"死区时间对电压源有源整流器从电网提取的输入电流谐波值的影响","authors":"V. Kus, T. Josefová","doi":"10.1109/AE.2014.7011692","DOIUrl":null,"url":null,"abstract":"This paper presents an effect of dead times on values of an input current harmonics drawn from an electric grid by a voltage-source active rectifier. The first part shows a derivation of the effect on one pulse of the voltage and then the values of the current harmonics are derived. The main section discusses a description of voltage with the pulse width modulation with respect to the dead time. A voltage waveform at the input terminals of the inverter, its harmonic analysis, and calculations of the current harmonics values are derived. The last part shows simulations and comparison of the harmonic analysis of the current with and without dead times.","PeriodicalId":149779,"journal":{"name":"2014 International Conference on Applied Electronics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Effect of dead times on the values of input current harmonics drawn from the grid by a voltage-source active rectifier\",\"authors\":\"V. Kus, T. Josefová\",\"doi\":\"10.1109/AE.2014.7011692\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an effect of dead times on values of an input current harmonics drawn from an electric grid by a voltage-source active rectifier. The first part shows a derivation of the effect on one pulse of the voltage and then the values of the current harmonics are derived. The main section discusses a description of voltage with the pulse width modulation with respect to the dead time. A voltage waveform at the input terminals of the inverter, its harmonic analysis, and calculations of the current harmonics values are derived. The last part shows simulations and comparison of the harmonic analysis of the current with and without dead times.\",\"PeriodicalId\":149779,\"journal\":{\"name\":\"2014 International Conference on Applied Electronics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Applied Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AE.2014.7011692\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Applied Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AE.2014.7011692","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effect of dead times on the values of input current harmonics drawn from the grid by a voltage-source active rectifier
This paper presents an effect of dead times on values of an input current harmonics drawn from an electric grid by a voltage-source active rectifier. The first part shows a derivation of the effect on one pulse of the voltage and then the values of the current harmonics are derived. The main section discusses a description of voltage with the pulse width modulation with respect to the dead time. A voltage waveform at the input terminals of the inverter, its harmonic analysis, and calculations of the current harmonics values are derived. The last part shows simulations and comparison of the harmonic analysis of the current with and without dead times.