磁共振胆管造影在医院小儿患者中的应用

Feni Try Sabdo, F. Fatimah, D. Darmini
{"title":"磁共振胆管造影在医院小儿患者中的应用","authors":"Feni Try Sabdo, F. Fatimah, D. Darmini","doi":"10.31983/jimed.v4i2.3998","DOIUrl":null,"url":null,"abstract":"Background : On examination MRCP patient pediatric in Radiology Hospital Santo Borromeus using tools made of PVC. But the use of such aids has a deficiency, ie the size is too large so that there is a distance between objects to be checked with body coils that can reducing value of the signal generated. The purpose of this research is to know the design of equipment tools investigation MRCP pediatric examination, difference of image quality and anatomical information resulting from the use of standard hospital aids and modification aids. Methods : This research is a quantitative research with experimental approach to design of modification aids in water phantom and patient pediatric examination MRCP sequence T2 FRFSE axial. The test was performed on image quality that was statistically analyzed by paired T test using SPSS 22. Beside that, the test was also conducted on anatomy information which was assessed by 2 radiologists with qualitative assessment. Results : The results of this study there are significant differences in SNR between the use of standard hospital aids and modification tools with p value 0.001. CNR differences were also significant between the use of standard hospital aids and modification aids with p value 0.001 (p <0.05). Conclusion : The results of image quality and anatomical information showed the best results in the use of tools modifications.","PeriodicalId":205622,"journal":{"name":"Jurnal Imejing Diagnostik (JImeD)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"DESIGN OF MODIFICATION EQUIPMENT TOOLS INVESTIGATION MAGNETIC RESONANCE CHOLANGIOPANCREATOGRAPHY PEDIATRIC PATIENTS IN HOSPITAL SANTO BORROMEUS BANDUNG\",\"authors\":\"Feni Try Sabdo, F. Fatimah, D. Darmini\",\"doi\":\"10.31983/jimed.v4i2.3998\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background : On examination MRCP patient pediatric in Radiology Hospital Santo Borromeus using tools made of PVC. But the use of such aids has a deficiency, ie the size is too large so that there is a distance between objects to be checked with body coils that can reducing value of the signal generated. The purpose of this research is to know the design of equipment tools investigation MRCP pediatric examination, difference of image quality and anatomical information resulting from the use of standard hospital aids and modification aids. Methods : This research is a quantitative research with experimental approach to design of modification aids in water phantom and patient pediatric examination MRCP sequence T2 FRFSE axial. The test was performed on image quality that was statistically analyzed by paired T test using SPSS 22. Beside that, the test was also conducted on anatomy information which was assessed by 2 radiologists with qualitative assessment. Results : The results of this study there are significant differences in SNR between the use of standard hospital aids and modification tools with p value 0.001. CNR differences were also significant between the use of standard hospital aids and modification aids with p value 0.001 (p <0.05). Conclusion : The results of image quality and anatomical information showed the best results in the use of tools modifications.\",\"PeriodicalId\":205622,\"journal\":{\"name\":\"Jurnal Imejing Diagnostik (JImeD)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Imejing Diagnostik (JImeD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31983/jimed.v4i2.3998\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Imejing Diagnostik (JImeD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31983/jimed.v4i2.3998","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:对Santo Borromeus放射医院的MRCP患儿使用PVC制成的工具进行检查。但使用这种辅助装置有一个缺点,即尺寸太大,使被检物体与体线圈之间有一定距离,从而降低了产生的信号值。本研究的目的是了解MRCP儿童检查设备工具的设计,以及使用标准医院辅助设备和改装辅助设备所产生的图像质量和解剖信息的差异。方法:本研究采用实验方法设计水影修饰辅助装置和患儿检查MRCP序列T2 FRFSE轴向进行定量研究。图像质量检验采用SPSS 22进行配对T检验。除此之外,还对解剖信息进行了测试,由2名放射科医师进行定性评估。结果:本研究结果显示,使用标准医院辅助工具和改良工具的信噪比有显著差异,p值为0.001。使用标准医院辅助器具与改良辅助器具的CNR差异也显著,p值为0.001 (p <0.05)。结论:图像质量和解剖信息显示使用工具修饰效果最好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
DESIGN OF MODIFICATION EQUIPMENT TOOLS INVESTIGATION MAGNETIC RESONANCE CHOLANGIOPANCREATOGRAPHY PEDIATRIC PATIENTS IN HOSPITAL SANTO BORROMEUS BANDUNG
Background : On examination MRCP patient pediatric in Radiology Hospital Santo Borromeus using tools made of PVC. But the use of such aids has a deficiency, ie the size is too large so that there is a distance between objects to be checked with body coils that can reducing value of the signal generated. The purpose of this research is to know the design of equipment tools investigation MRCP pediatric examination, difference of image quality and anatomical information resulting from the use of standard hospital aids and modification aids. Methods : This research is a quantitative research with experimental approach to design of modification aids in water phantom and patient pediatric examination MRCP sequence T2 FRFSE axial. The test was performed on image quality that was statistically analyzed by paired T test using SPSS 22. Beside that, the test was also conducted on anatomy information which was assessed by 2 radiologists with qualitative assessment. Results : The results of this study there are significant differences in SNR between the use of standard hospital aids and modification tools with p value 0.001. CNR differences were also significant between the use of standard hospital aids and modification aids with p value 0.001 (p <0.05). Conclusion : The results of image quality and anatomical information showed the best results in the use of tools modifications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信