{"title":"DC-DC降压变换器传导辐射分析","authors":"Secil Genc, B. Gundogdu, O. Ozgonenel","doi":"10.1109/gpecom55404.2022.9815712","DOIUrl":null,"url":null,"abstract":"This work discusses measurements and modeling of conducted emissions in the time and frequency domain to evaluate the impact of common DC/DC converters existing on DC grids. Variable DC input voltages are used to study the influence of input voltage on the LISN and conducted emissions. The time-frequency domain was shown to provide extra information to assess conducted emissions in addition to the time- and frequency-domain representations. PSIM software was used to model the system, and MATLAB was used to analyze the signals. Short-time Fourier transform (STFT) and spectrogram of the signal have been employed for the evaluation of conducted emissions. According to the results when the input voltage rose, the amplitude of the transmitted propagation decreased. In the future, the findings might be applied to the design of EMI filters.","PeriodicalId":441321,"journal":{"name":"2022 4th Global Power, Energy and Communication Conference (GPECOM)","volume":"34 45","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Conducted Emissions Analysis of DC-DC Buck Converter\",\"authors\":\"Secil Genc, B. Gundogdu, O. Ozgonenel\",\"doi\":\"10.1109/gpecom55404.2022.9815712\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work discusses measurements and modeling of conducted emissions in the time and frequency domain to evaluate the impact of common DC/DC converters existing on DC grids. Variable DC input voltages are used to study the influence of input voltage on the LISN and conducted emissions. The time-frequency domain was shown to provide extra information to assess conducted emissions in addition to the time- and frequency-domain representations. PSIM software was used to model the system, and MATLAB was used to analyze the signals. Short-time Fourier transform (STFT) and spectrogram of the signal have been employed for the evaluation of conducted emissions. According to the results when the input voltage rose, the amplitude of the transmitted propagation decreased. In the future, the findings might be applied to the design of EMI filters.\",\"PeriodicalId\":441321,\"journal\":{\"name\":\"2022 4th Global Power, Energy and Communication Conference (GPECOM)\",\"volume\":\"34 45\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 4th Global Power, Energy and Communication Conference (GPECOM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/gpecom55404.2022.9815712\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 4th Global Power, Energy and Communication Conference (GPECOM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/gpecom55404.2022.9815712","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文讨论了传导辐射在时域和频域的测量和建模,以评估现有的普通DC/DC转换器对直流电网的影响。采用可变直流输入电压,研究了输入电压对LISN和传导发射的影响。结果表明,除了时域和频域表示外,时频域还提供了评估传导辐射的额外信息。采用PSIM软件对系统进行建模,并利用MATLAB对信号进行分析。利用短时傅立叶变换(STFT)和信号谱图对传导辐射进行了评价。结果表明,当输入电压升高时,传输传播幅值减小。在未来,研究结果可应用于电磁干扰滤波器的设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Conducted Emissions Analysis of DC-DC Buck Converter
This work discusses measurements and modeling of conducted emissions in the time and frequency domain to evaluate the impact of common DC/DC converters existing on DC grids. Variable DC input voltages are used to study the influence of input voltage on the LISN and conducted emissions. The time-frequency domain was shown to provide extra information to assess conducted emissions in addition to the time- and frequency-domain representations. PSIM software was used to model the system, and MATLAB was used to analyze the signals. Short-time Fourier transform (STFT) and spectrogram of the signal have been employed for the evaluation of conducted emissions. According to the results when the input voltage rose, the amplitude of the transmitted propagation decreased. In the future, the findings might be applied to the design of EMI filters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信