用于测量人工光辐射(AOR)照射的个人剂量计

Alessandro Quarto, V. Di Lecce, R. Dario, J. Uva
{"title":"用于测量人工光辐射(AOR)照射的个人剂量计","authors":"Alessandro Quarto, V. Di Lecce, R. Dario, J. Uva","doi":"10.1109/CIMSA.2011.6059927","DOIUrl":null,"url":null,"abstract":"The Italian Legislative Decree dated April 26, 2010 no. 81/08 also refers to the European directive no. 2006/25/EC on the limit values for the exposure of workers to artificial optical radiation (AOR). The main damages caused by higher exposure to AOR regard in particular eyes and all of the body (e.g. skin). Recent studies concern the health effects on retinal photoreceptors after exposure to wavelength range between 380 nm and 500 nm, named \"blue light”. The aim of this paper is to present an innovative personal dosimeter for AOR detection. The proposed system can be used not only for evaluating AOR, but also providing the operator's position and attitude in relation to the natural or artificial source of radiation. The acquired Data are then processed by a Fuzzy Inference System (FIS). The FIS main target is the accurate evaluation of risk levels associated to each light radiation striking the operator's retina.","PeriodicalId":422972,"journal":{"name":"2011 IEEE International Conference on Computational Intelligence for Measurement Systems and Applications (CIMSA) Proceedings","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Personal dosimeter for the measurement of artificial optical radiation (AOR) exposure\",\"authors\":\"Alessandro Quarto, V. Di Lecce, R. Dario, J. Uva\",\"doi\":\"10.1109/CIMSA.2011.6059927\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Italian Legislative Decree dated April 26, 2010 no. 81/08 also refers to the European directive no. 2006/25/EC on the limit values for the exposure of workers to artificial optical radiation (AOR). The main damages caused by higher exposure to AOR regard in particular eyes and all of the body (e.g. skin). Recent studies concern the health effects on retinal photoreceptors after exposure to wavelength range between 380 nm and 500 nm, named \\\"blue light”. The aim of this paper is to present an innovative personal dosimeter for AOR detection. The proposed system can be used not only for evaluating AOR, but also providing the operator's position and attitude in relation to the natural or artificial source of radiation. The acquired Data are then processed by a Fuzzy Inference System (FIS). The FIS main target is the accurate evaluation of risk levels associated to each light radiation striking the operator's retina.\",\"PeriodicalId\":422972,\"journal\":{\"name\":\"2011 IEEE International Conference on Computational Intelligence for Measurement Systems and Applications (CIMSA) Proceedings\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE International Conference on Computational Intelligence for Measurement Systems and Applications (CIMSA) Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIMSA.2011.6059927\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Conference on Computational Intelligence for Measurement Systems and Applications (CIMSA) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIMSA.2011.6059927","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

2010年4月26日意大利立法法令81/08也指欧洲第81/08号指令。2006/25/EC关于工人接触人工光辐射(AOR)的极限值。高暴露于AOR造成的主要损害,特别是眼睛和全身(如皮肤)。最近的研究关注的是暴露在波长在380纳米到500纳米之间的“蓝光”下对视网膜感光器的健康影响。本文的目的是提出一种用于AOR检测的创新个人剂量计。所提出的系统不仅可以用于评估AOR,还可以提供操作员与自然或人工辐射源相关的位置和姿态。然后用模糊推理系统(FIS)对采集的数据进行处理。FIS的主要目标是准确评估与每次照射到操作者视网膜的光辐射相关的风险水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Personal dosimeter for the measurement of artificial optical radiation (AOR) exposure
The Italian Legislative Decree dated April 26, 2010 no. 81/08 also refers to the European directive no. 2006/25/EC on the limit values for the exposure of workers to artificial optical radiation (AOR). The main damages caused by higher exposure to AOR regard in particular eyes and all of the body (e.g. skin). Recent studies concern the health effects on retinal photoreceptors after exposure to wavelength range between 380 nm and 500 nm, named "blue light”. The aim of this paper is to present an innovative personal dosimeter for AOR detection. The proposed system can be used not only for evaluating AOR, but also providing the operator's position and attitude in relation to the natural or artificial source of radiation. The acquired Data are then processed by a Fuzzy Inference System (FIS). The FIS main target is the accurate evaluation of risk levels associated to each light radiation striking the operator's retina.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信