{"title":"设计三相异步电动机在线监测与灵敏故障检测系统","authors":"D. A. Asfani, H. Z. Mubarok, Arif Musthofa, I. M. Yulistya Negara","doi":"10.1109/ICELMACH.2014.6960438","DOIUrl":null,"url":null,"abstract":"On-line monitoring system is one of the solutions to avoid catastrophic failure in machine, including induction motor. The most common fault in induction motor is stator winding failures that initiated by inter-turn short circuit. In this paper, induction motor monitoring and fault detection system is proposed based on microcontroller which is displayed on computer monitor. Several measurement variables are displayed in on-line monitoring interface such as voltage, current, speed, and stator temperature. Moreover, the diagnostic system is developed to detect inter-turn short circuit. Based on the testing result, the proposed system is successfully to detect one-turn short circuit fault or less than one percent of stator winding.","PeriodicalId":288960,"journal":{"name":"2014 International Conference on Electrical Machines (ICEM)","volume":"38 4","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design on-line monitoring and sensitive fault detection for three phase induction motor\",\"authors\":\"D. A. Asfani, H. Z. Mubarok, Arif Musthofa, I. M. Yulistya Negara\",\"doi\":\"10.1109/ICELMACH.2014.6960438\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"On-line monitoring system is one of the solutions to avoid catastrophic failure in machine, including induction motor. The most common fault in induction motor is stator winding failures that initiated by inter-turn short circuit. In this paper, induction motor monitoring and fault detection system is proposed based on microcontroller which is displayed on computer monitor. Several measurement variables are displayed in on-line monitoring interface such as voltage, current, speed, and stator temperature. Moreover, the diagnostic system is developed to detect inter-turn short circuit. Based on the testing result, the proposed system is successfully to detect one-turn short circuit fault or less than one percent of stator winding.\",\"PeriodicalId\":288960,\"journal\":{\"name\":\"2014 International Conference on Electrical Machines (ICEM)\",\"volume\":\"38 4\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Electrical Machines (ICEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICELMACH.2014.6960438\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Electrical Machines (ICEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICELMACH.2014.6960438","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在线监测系统是避免包括感应电机在内的机械发生灾难性故障的解决方案之一。异步电动机中最常见的故障是由匝间短路引起的定子绕组故障。本文提出了一种基于单片机的感应电动机监测与故障检测系统,并将其显示在计算机显示器上。几个测量变量显示在在线监测界面,如电压,电流,速度,定子温度。此外,还开发了匝间短路检测系统。测试结果表明,该系统可成功检测出1匝短路故障或小于1%的定子绕组故障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design on-line monitoring and sensitive fault detection for three phase induction motor
On-line monitoring system is one of the solutions to avoid catastrophic failure in machine, including induction motor. The most common fault in induction motor is stator winding failures that initiated by inter-turn short circuit. In this paper, induction motor monitoring and fault detection system is proposed based on microcontroller which is displayed on computer monitor. Several measurement variables are displayed in on-line monitoring interface such as voltage, current, speed, and stator temperature. Moreover, the diagnostic system is developed to detect inter-turn short circuit. Based on the testing result, the proposed system is successfully to detect one-turn short circuit fault or less than one percent of stator winding.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信