交流轧机传动的应用策略

H. Hakata, R. Kurosawa, S. Tatara, C. Lemone, H. Hosoda
{"title":"交流轧机传动的应用策略","authors":"H. Hakata, R. Kurosawa, S. Tatara, C. Lemone, H. Hosoda","doi":"10.1109/IAS.1991.178006","DOIUrl":null,"url":null,"abstract":"It is demonstrated that by properly selecting a suitable cycloconverter-fed AC drive system for a prospective rolling mill one can expect not only an excellent performance and responsive controls, but also a minimum consumption of incoming power and reduction of running energy cost. A noncirculating current cycloconverter drive is the most suitable for large-scale and low-speed drives, such as hot reversing mill main stands, while a circulating current cycloconverter drive is best suited for a tandem cold mill, which requires a high capability of speed control. The system can drive the mill at a quick speed response of omega /sub c/=60 rad/s in a wide speed range. This control performance increases the possibilities for improvements in the gage thickness accuracy control and in the production yield rate.<<ETX>>","PeriodicalId":294244,"journal":{"name":"Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Application strategies for AC rolling mill drives\",\"authors\":\"H. Hakata, R. Kurosawa, S. Tatara, C. Lemone, H. Hosoda\",\"doi\":\"10.1109/IAS.1991.178006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is demonstrated that by properly selecting a suitable cycloconverter-fed AC drive system for a prospective rolling mill one can expect not only an excellent performance and responsive controls, but also a minimum consumption of incoming power and reduction of running energy cost. A noncirculating current cycloconverter drive is the most suitable for large-scale and low-speed drives, such as hot reversing mill main stands, while a circulating current cycloconverter drive is best suited for a tandem cold mill, which requires a high capability of speed control. The system can drive the mill at a quick speed response of omega /sub c/=60 rad/s in a wide speed range. This control performance increases the possibilities for improvements in the gage thickness accuracy control and in the production yield rate.<<ETX>>\",\"PeriodicalId\":294244,\"journal\":{\"name\":\"Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1991.178006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1991.178006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

结果表明,为某轧机选择合适的环变流器交流驱动系统,不仅可以获得优异的性能和响应性控制,而且可以使输入功率消耗最小,降低运行能量成本。非循环电流环变传动最适合于大型低速传动,如热可逆轧机主机架,而循环电流环变传动最适合于对速度控制能力要求较高的冷连轧机。该系统能在较宽的转速范围内以omega /sub /=60 rad/s的速度响应驱动磨机。这种控制性能增加了改善量具厚度精度控制和生产成品率的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application strategies for AC rolling mill drives
It is demonstrated that by properly selecting a suitable cycloconverter-fed AC drive system for a prospective rolling mill one can expect not only an excellent performance and responsive controls, but also a minimum consumption of incoming power and reduction of running energy cost. A noncirculating current cycloconverter drive is the most suitable for large-scale and low-speed drives, such as hot reversing mill main stands, while a circulating current cycloconverter drive is best suited for a tandem cold mill, which requires a high capability of speed control. The system can drive the mill at a quick speed response of omega /sub c/=60 rad/s in a wide speed range. This control performance increases the possibilities for improvements in the gage thickness accuracy control and in the production yield rate.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信