孟加拉国低频控制方案减少窃电现象

Md. Saiam, Shah Salimullah, Md. Shoab Akther, M. Zahidul Islam, Tanjir Hossain Bhuiyan
{"title":"孟加拉国低频控制方案减少窃电现象","authors":"Md. Saiam, Shah Salimullah, Md. Shoab Akther, M. Zahidul Islam, Tanjir Hossain Bhuiyan","doi":"10.1109/STI50764.2020.9350450","DOIUrl":null,"url":null,"abstract":"Electricity theft is a common issue from the beginning of electricity generation and irreparable losses for the whole country. The most common and simplest methods of stealing electricity is tapping or hooking electricity directly from the distribution line. This paper presents an advanced protection method to protect the electricity theft directly from the distribution line. On the distribution side, the system converts the frequency of electricity into 6Hz to 7Hz range, and in the consumer end, it again converts the frequency into 50Hz by using an authorized meter. This method is totally completed by frequency variation in the distribution line which reduces the maximum electricity theft occurs in the distribution side of Bangladesh.","PeriodicalId":242439,"journal":{"name":"2020 2nd International Conference on Sustainable Technologies for Industry 4.0 (STI)","volume":"37 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Reducing Electricity Theft by Low Frequency Control Scheme in Bangladesh\",\"authors\":\"Md. Saiam, Shah Salimullah, Md. Shoab Akther, M. Zahidul Islam, Tanjir Hossain Bhuiyan\",\"doi\":\"10.1109/STI50764.2020.9350450\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electricity theft is a common issue from the beginning of electricity generation and irreparable losses for the whole country. The most common and simplest methods of stealing electricity is tapping or hooking electricity directly from the distribution line. This paper presents an advanced protection method to protect the electricity theft directly from the distribution line. On the distribution side, the system converts the frequency of electricity into 6Hz to 7Hz range, and in the consumer end, it again converts the frequency into 50Hz by using an authorized meter. This method is totally completed by frequency variation in the distribution line which reduces the maximum electricity theft occurs in the distribution side of Bangladesh.\",\"PeriodicalId\":242439,\"journal\":{\"name\":\"2020 2nd International Conference on Sustainable Technologies for Industry 4.0 (STI)\",\"volume\":\"37 \",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 2nd International Conference on Sustainable Technologies for Industry 4.0 (STI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/STI50764.2020.9350450\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 2nd International Conference on Sustainable Technologies for Industry 4.0 (STI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/STI50764.2020.9350450","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

窃电是一个从发电开始就存在的普遍问题,对整个国家造成了不可弥补的损失。最常见和最简单的偷电方法是直接从配电线路上接电或钩电。本文提出了一种防止配电线路直接盗电的先进保护方法。在配电端,系统将电力的频率转换为6Hz到7Hz的范围,在用户端,通过使用授权的电表再次将频率转换为50Hz。这种方法完全通过配电线路的频率变化来完成,从而最大限度地减少了孟加拉国配电侧的窃电现象。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reducing Electricity Theft by Low Frequency Control Scheme in Bangladesh
Electricity theft is a common issue from the beginning of electricity generation and irreparable losses for the whole country. The most common and simplest methods of stealing electricity is tapping or hooking electricity directly from the distribution line. This paper presents an advanced protection method to protect the electricity theft directly from the distribution line. On the distribution side, the system converts the frequency of electricity into 6Hz to 7Hz range, and in the consumer end, it again converts the frequency into 50Hz by using an authorized meter. This method is totally completed by frequency variation in the distribution line which reduces the maximum electricity theft occurs in the distribution side of Bangladesh.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信