{"title":"鞋类阻力与通过鞋类和地板的个人接地的关系","authors":"J. Smallwood, D. Swenson, T. Viheriäkoski","doi":"10.23919/EOS/ESD.2018.8509789","DOIUrl":null,"url":null,"abstract":"ESD control footwear is qualified using resistance measurements for use in explosives handling facilities. This paper explores the relationship between footwear resistance and the personal grounding performance in terms of measured resistance from body to ground and body voltage generated in a walk test with ’’antistatic’’ and ’’conductive’’ floors.","PeriodicalId":328499,"journal":{"name":"2018 40th Electrical Overstress/Electrostatic Discharge Symposium (EOS/ESD)","volume":"8 2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Relationship between footwear resistance and personal grounding through footwear and flooring\",\"authors\":\"J. Smallwood, D. Swenson, T. Viheriäkoski\",\"doi\":\"10.23919/EOS/ESD.2018.8509789\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ESD control footwear is qualified using resistance measurements for use in explosives handling facilities. This paper explores the relationship between footwear resistance and the personal grounding performance in terms of measured resistance from body to ground and body voltage generated in a walk test with ’’antistatic’’ and ’’conductive’’ floors.\",\"PeriodicalId\":328499,\"journal\":{\"name\":\"2018 40th Electrical Overstress/Electrostatic Discharge Symposium (EOS/ESD)\",\"volume\":\"8 2\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 40th Electrical Overstress/Electrostatic Discharge Symposium (EOS/ESD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/EOS/ESD.2018.8509789\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 40th Electrical Overstress/Electrostatic Discharge Symposium (EOS/ESD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/EOS/ESD.2018.8509789","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Relationship between footwear resistance and personal grounding through footwear and flooring
ESD control footwear is qualified using resistance measurements for use in explosives handling facilities. This paper explores the relationship between footwear resistance and the personal grounding performance in terms of measured resistance from body to ground and body voltage generated in a walk test with ’’antistatic’’ and ’’conductive’’ floors.